Instructions for the Installer

14. INSTALLING THE APPLIANCE

14.1 Electrical connection
The nameplate with the technical data, serial number and mark is in a
visible position on the oven door frame.
The nameplate must never be removed.
The appliance must be connected to earth in compliance with electrical
system safety regulations.
If a permanent connection is used, the appliance's power supply line must
be fitted with an omnipolar breaking device with contact gap of at least
3 mm, located in an easily accessible position close to the appliance itself.
If a socket and plug connection is used, check that they are of the same
type. Do not use reducers, adapters or junctions since they may cause
overheating or burns.
14.1.1 Ovens with hob controls
On ovens with hob controls the power supply lead is not supplied. Use
a H05RR-F or H05RN-F rubber cable and when positioning it ensure that
it does not touch the metal parts of the appliance's external casing.
To access the terminal board, remove the appliance's back cover by
unscrewing the relative screws. If necessary, change the positions of the
jumpers on the terminal board as shown, then connect the wires, making
sure that the earth wire is at least 20 mm longer. Fix the power supply lead
to the appliance using the cable clamp provided.