Adjusting For Natural Gas; Adjusting The Primary Air Flow; Reassembling The Hob Skin - Smeg GKL64-3 Instructions For Use Manual

Smeg cooktop instructions for use
Table of Contents

Advertisement

5.4

Adjusting for natural gas

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the
appliance to the condition required to use this type of gas, proceed as described in point "5.2
Adjusting for bottled gas" but select the nozzles and adjust the primary air flow for natural gas,
as indicated in the table below and in point "5.5 Adjusting the primary air flow".
Burner
Auxiliary
Semi rapid
Rapid (3)
Rapid (7)
Rapid (6)
Ultra-Rapid
Double
Crown (4)
Double
Crown (8)
5.5

Adjusting the primary air flow

Refers to the gap "X" in mm.
BURNER
Auxiliary
Semi rapid
Rapid (3)
Rapid (7)
Rapid (6)
Ultra-Rapido
Double
Crown (4)
Double
Crown (8)
To identify the burners on your hob, refer to the drawings in point "5.8 Hob burner
layout"
5.6

Reassembling the hob skin

Reverse the procedure described in point "5.1 Removing the hob skin ".
When replacing the burner rings, bear in mind that they must be fully tightened using
the spanner provided.
Put the pan stands back in place, fitting first those at the side and then the central one.
28
Instructions for the Installer
Nominal
heat
capacity
(kW)
1.05
1.7
3.5
2.9
3.1
4.2
Internal
0.9
External
3.3
Internal
0.9
External
4.0
G20
20 mbar
2.0
2.0
2.5
2.5
2.5
2.5
Internal
5.0
10.0
External
Internal
5.0
13.0
External
Natural gas – G20 20 mbar
Nozzle diameter
Reduced heat capacity
1/100 mm
132
165
250
230
240
300
126
250
126
140
G30/G31
30/37 mbar
10.0
10.0
8.0
8.0
10.0
12.0
5.0
10.0
5.0
13.0
(W)
400
500
900
1.05
900
1100
400
1200
400
1200
G110
8 mbar
1.0
1.5
2.0
1.5
1.0
5.0
1.0
2.5
1.0
3.5

Advertisement

Table of Contents
loading

Table of Contents