5-8. When the Fan does not operate (F, R, M, C - FAN)
- This refrigerator uses the BLDC Fan Motor. The BLDC Motor operates with DC 7~12V.
- Under Comp On conditions, the R-Fan operates generally. But, when the ambient temperature is high or when
you open and close the Door once, it operates after one-minute delay. So, don't get misled by it. It is normal.
- When there is defect, turn on the Self-Diagnosis function and confirm the defect before turning off the
unit.
C-FAN
Voltage between MAIN PCB
GND and CN74 #6 is measured
about DC8~12V?
No
CV-FAN
Voltage between MAIN PCB
GND and CN74 #5 is
measured about DC8~12V?
No
R-FAN
Voltage between MAIN PCB
GND and CN74 #3 is measured
about DC8~12V?
No
Read with the Door
No
closed : Open – 5V,
Closed – 0V
Start
COMP is running?
Yes
F-FAN
Voltage between MAIN PCB
GND and CN74 #4 is measured
about DC8~12V?
No
Are the Freezer, the Fridge
and the Door Switches
closed?
Yes
No
Turn on Forced Operation.
Yes
FAN works normal.
No
Check after closing the Door
When there is door alarm
sound, repair the Door
Switch Connector.