Piping Installation; Preparing Refrigerant Piping; Refrigerant Piping Requirements; Refrigerant Piping Material - Daikin RXYSA4A7V1B Installer And User Manual

System air conditioner
Table of Contents

Advertisement

18 Piping installation

In this chapter

18.1 Preparing refrigerant piping

18.1.1 Refrigerant piping requirements

18.1.2 Refrigerant piping material

RXYSA4~6A7V/Y1B
VRV 5-S system air conditioner
4P600330-1A - 2020.07
18.1
Preparing refrigerant piping ...................................................................................................................................................
18.1.1
Refrigerant piping requirements ...........................................................................................................................
18.1.2
Refrigerant piping material ....................................................................................................................................
18.1.3
To select the piping size .........................................................................................................................................
18.1.4
To select refrigerant branch kits............................................................................................................................
18.1.5
Refrigerant piping length and height difference ...................................................................................................
18.2
Connecting the refrigerant piping..........................................................................................................................................
18.2.1
About connecting the refrigerant piping...............................................................................................................
18.2.2
Precautions when connecting the refrigerant piping............................................................................................
18.2.3
Pipe bending guidelines .........................................................................................................................................
18.2.4
To braze the pipe end ............................................................................................................................................
18.2.5
Using the stop valve and service port....................................................................................................................
18.2.6
To remove the spun pipes .....................................................................................................................................
18.2.7
To connect the refrigerant piping to the outdoor unit .........................................................................................
18.2.8
To connect the refrigerant branching kit ..............................................................................................................
18.3
Checking the refrigerant piping..............................................................................................................................................
18.3.1
About checking the refrigerant piping...................................................................................................................
18.3.2
Checking refrigerant piping: General guidelines ...................................................................................................
18.3.3
Checking refrigerant piping: Setup ........................................................................................................................
18.3.4
To perform a leak test............................................................................................................................................
18.3.5
To perform vacuum drying ....................................................................................................................................
INFORMATION
Also read the precautions and requirements in the "General safety precautions"
chapter.
NOTICE
The piping and other pressure-containing parts shall be suitable for refrigerant. Use
phosphoric acid deoxidised seamless copper for refrigerant.
Foreign materials inside pipes (including oils for fabrication) must be
≤30 mg/10 m.
Piping material: Phosphoric acid deoxidised seamless copper.
Flare connections: Only use annealed material.
Piping temper grade and thickness:
Outer diameter (Ø)
6.4 mm (1/4")
9.5 mm (3/8")
12.7 mm (1/2")
15.9 mm (5/8")
19.1 mm (3/4")
Temper grade
Annealed (O)
≥0.80 mm
Annealed (O)
≥0.99 mm
Half hard (1/2H)
≥0.80 mm
18
Piping installation
|
(a)
Thickness (t)
Installer and user reference guide
77
77
77
78
79
80
81
81
81
82
82
83
84
85
87
88
88
89
90
90
91
Ø
t
77

Advertisement

Table of Contents
loading