For operation on 380-415V 3N~: use an H05V2V2-F type five-core
2
cable (5 x 4 mm
).
For operation on 380-415V 2N~: use an H05V2V2-F type four-core
2
cable (4 x 6 mm
).
Operation at 220-240V~: use a 3 x 10mm² three-core cable:
This type of connection is permitted solely using the special kit
available at Service Centres (part. no. KITMT code 902263)
The earth wire (yellow-green) must be at least 20 mm longer than
the other wires at the end for connection to the appliance.
WARNING: The values indicated above refer to the cross-section of the internal conductor.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGE TO PERSONS OR THINGS
CAUSED BY NON-OBSERVANCE OF THE ABOVE PRESCRIPTIONS.

15.2 Positioning and levelling the appliance (depending on model)

After making the electrical connections, level the appliance on the ground by means of its four adjustable
feet. For good cooking results, the appliance must be properly levelled. Depending on the model you
have purchased, the foot height adjustment range may vary from 70 to 95 mm and from 110 to 160 mm.
These heights refer to the distance between the highest point of the foot (fixed part) and the lowest point
(movable part which rests on the floor).

15.3 Wall fixing

1 Fix the screw to the wall and hook the chain (B);
2 Hook the chain to the hole positioned at the rear of the cooker by the gas pipe (A);
3 Once the chain is in position, push the cooker against the wall;
4. The height of the screw hole from floor level must not exceed 800 mm (C).
Instructions for the installer
A
220-240V~
B
2
10 mm
20 mm
C
29