Item
Test Limit
Select Fiber End
Type
Cable ID Set
14
Table 6. Edit Project Menu (cont.)
Document Only is the default test limit and does not
compare the results to standards or indicate pass or fail.
Tap  to select a limit based on a standard.
Limits for the test are from standards such as
IEC 61300-3-35. The limits specify the maximum size and
number of scratches and defects allowed in the core or
cladding zones on the endface of the fiber.
When you select a limit for the test, the App can compare
the size, location, and number of scratches and defects to
the criteria of the limit, and give each fault and the
endface image a PASS or FAIL result.
Tap the image of the connector and select the end type
with the correct number of fibers.
To create a list of sequential cable IDs, enter the First ID
and Last ID for the list.
When you save results, you can use the IDs sequentially, or
you can select or create a different ID for a result.
An ID can have a maximum of 60 characters.
A project can have a maximum of 5000 IDs.
Only alphanumeric characters increment.
The characters in each position in the First ID and Last ID
must have the same format:
The IDs must be the same length.
The characters in each position must be the same type
(letters, numbers, or symbols).
The characters in each position must be the same case.
The IDs show in red text if the formats do not match.
Description