Additional Specific Conditions Of Use (X) When "Xa" Designation Is; Guard Din Style Sensors Against Impacts Greater Than 4J; Range At Sensor; C To +70 °C - Emerson Rosemount 148 Quick Start Manual

Temperature transmitter
Hide thumbs Also See for Rosemount 148:
Table of Contents

Advertisement

Quick Start Guide
Process Temperature

Range at Sensor

Connection
-60 °C to +80 °C
Sensor Connection is where the sensor threads into the
(1)
transmitter or junction box housing.
5.7 
International
5.7.1  E7 IECEx Flameproof and Dust
Certificate
Standards
Markings
Specific Conditions of Safe Use (X):
1. Flameproof joints are not intended for repair.
2. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that cause electrostatic build-up
on painted surfaces, and only clean the painted surfaces with a
damp cloth. If paint is ordered through a special option code,
contact the manufacturer for more information.

Additional Specific Conditions of Use (X) when "XA" designation is

ordered:

1. Guard DIN Style sensors against impacts greater than 4J.

2. The spring loaded adapter style sensors and DIN style sensors
must be installed in a thermowell to maintain Ex tb protection.
Process Temperature
Range at Sensor
Connection
-60 °C to +70 °C
-60 °C to +80 °C
-60 °C to +80 °C
Sensor Connection is where the sensor threads into the
(1)
transmitter or junction box housing.
20
Ambient Temperature
Range (°C)
(°C)
(1)
-60 °C to +80 °C
IECEx DEK 19.0041X
EC 60079-0:2017, IEC 60079-1:2014, IEC 60079-31:2013
Ex db IIC T6...T1 Gb, T6 (-60 °C ≤ T
°C ≤ Ta ≤ +80 °C); Ex tb IIIC T130°C Db, (-60 °C ≤ T
°C) See
Tables
for process temperatures.
Ambient Temperature
Range (°C)
(1)
(°C)
-60 °C to +70 °C
-60 °C to +80 °C
-60 °C to +80 °C
April 2024
Maximum surface
temperature "T"
T130 °C
≤ +70 °C), T5...T1 (-60
a
a
Temperature Class /
Maximum Surface
Temperature "T"
T6
T5...T1
T 130 °C
Emerson.com/Rosemount
≤ +80

Advertisement