Bose FreeSpace IZA 2120-HZ Service Manual page 16

Integrated zone amplifier / zone amplifier
Hide thumbs Also See for FreeSpace IZA 2120-HZ:
Table of Contents

Advertisement

FreeSpace
AC Current Draw and Thermal Dissipation Information
Load Configuration
Test Signal & Power Level
(Both IZA channels driven)
Power On, Idling
1/8th Rated Power
IEC65 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
1/3rd Rated Power
IEC65 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
Mechanical Diagrams
Product Information
IZA 2120-LZ
®
Total Audio
Output, W
0
8Ω / Ch
15
4Ω / Ch
30
8Ω / Ch
40
4Ω / Ch
80
120VAC 60Hz.
230VAC 50Hz.
Line Current, A
Line Current, A
0.16
0.13
0.19
0.15
0.50
0.28
0.25
0.17
1.00
0.539
Safety and Regulatory Compliance
The FreeSpace IZA 2120-LZ integrated zone
complies with CE requirements and is UL listed
according to UL60065 (7th edition) and CAN/CSA C22.2
No. 60065-03; CB approved, according to IEC60065
(7th edition), including group and national differences.
This model also complies with FCC Part 15B Class A
(2003), EN55103-1 (1997), EN55103-2 (1996), and
CISPR13 (2003) requirements.
Product Codes
120V – US
230V – EU
100V – Japan
230V – UK
240V – AU
Accessories
Volume control user interface (PC041966)
Volume control with A/B switch user interface (PC041967)
16
Thermal Dissipation, Max
Watts
BTU/hr.
kCal/hr.
30
102
26
34
116
29
64
218
55
39
133
34
136
464
117
719782-1420
719782-2420
719782-3420
719782-4420
719782-5420

Advertisement

Table of Contents
loading

Table of Contents