Bose FreeSpace IZA 2120-HZ Service Manual page 12

Integrated zone amplifier / zone amplifier
Hide thumbs Also See for FreeSpace IZA 2120-HZ:
Table of Contents

Advertisement

FreeSpace
AC Current Draw and Thermal Dissipation Information
Load Configuration
Test Signal & Power Level
(Both IZA channels driven)
Power On, Idling
1/8th Rated Power
IEC65 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
1/3rd Rated Power
IEC65 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
Mechanical Diagrams
Product Information
ZA 2120-HZ
®
Total Audio
Output, W
0
70V / Ch
30
100V / Ch
30
70V / Ch
80
100V / Ch
80
120VAC 60Hz.
230VAC 50Hz.
Line Current, A
Line Current, A
0.20
0.15
0.57
0.31
0.66
0.35
1.13
0.58
1.25
0.65
Safety and Regulatory Compliance
with CE requirements and is UL listed according to
UL60065 (7th edition) and CAN/CSA C22.2 No. 60065-
03; CB approved, according to IEC60065 (7th edition),
including group and national differences. This model
also complies with FCC Part 15B Class A (2003),
EN55103-1 (1997), EN55103-2 (1996), and CISPR13
(2003) requirements.
Product Codes
120V – US
230V – EU
100V – Japan
230V – UK
240V – AU
Accessories
Volume control user interface (PC041966)
12
Thermal Dissipation, Max
Watts
BTU/hr.
kCal/hr.
34
116
29
71
242
61
81
276
71
133
454
114
150
512
129
722196-1410
722196-2410
722196-3410
722196-4410
722196-5410

Advertisement

Table of Contents
loading

Table of Contents