Troubleshooting 4 - Midea MFYA400-24HRFN8-QRD0W User Manual

Floor-standing type air conditioner
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING
CAUTION
If any of the following conditions occurs, turn o your unit immediately!
• The power cord is damaged or abnormally warm
• You smell a burning odor
• The unit emits loud or abnormal sounds
• A power fuse blows or the circuit breaker frequently trips
• Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED
SERVICE PROVIDER IMMEDIATELY.
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue
Unit does not turn
on when pressing
ON/OFF button
The unit changes from
COOL/HEAT mode to
FAN mode
The indoor unit
emits white mist
Both the indoor and
outdoor units emit
white mist
The indoor unit makes
noises
Both the indoor unit
and outdoor unit make
noises
Possible Causes
The Unit has a 3-minute protection feature that prevents the unit from
overloading. The unit cannot be restarted within three minutes of being
turned o .
The unit may change its setting to prevent frost from forming on the unit.
Once the temperature increases, the unit will start operating in the
previously selected mode again.
The set temperature has been reached, at which point the unit turns o the
compressor. The unit will continue operating when the temperature
fluctuates again.
In humid regions, a large temperature di erence between the room's air
and the conditioned air can cause white mist.
When the unit restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process.
A squeaking sound is heard when the system is OFF or in COOL mode. The
noise is also heard when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit's plastic parts.
A low hissing sound may occur during operation. This is normal and is cau-
sed by refrigerant gas flowing through both the indoor and outdoor units.
A low hissing sound may be heard when the system starts, has just stopped
running or is defrosting. This noise is normal and is caused by the refrigerant
gas stopping or changing direction.