At the Heating step, if NTC resistance is measured beyond the specified resistance values or if the NTC resistance is measured as
open/short circuit, NTC fault occurs. When the fault is detected software skips the heating step and continues the program with
the next step.
The machine electronics monitors water counter pulses at every step of the washing program. If pulses are received from the counter at
any step other than Water-Inlet, a Water Inlet Error occurs.
When the fault is detected, software drives the drain pump for 1 minute then checks the counter signal again. If the signal exists, that
means the faulty condition still exists. The drain pump is activated with 1 minute intervals (1 min ON, 1 min. OFF).
December 12, 2018

NTC fault E:06

Possible reasons:
Malfunction of NTC
Cable harness errors
Faulty electronics

Water Inlet Valve Fault E:07

Possible reasons:
Malfunction of water inlet valve (stuck open or weeping)
Low water pressure
Faulty electronics
Troubleshooting