Incoming water to the machine is monitored via a water counter (flow meter) system. Water counter generates electronic pulses. During
the "Water Inlet" step (for any program including functional test) if no pulses could be sensed by the electronics, No Water condition
occurs. At this condition the dishwasher will wait until the water signal is detected. If the necessary water signal is
detected the machine will continue its normal operation.
The water temperature in the machine is measured by an NTC (negative temperature coefficient). NTC is simply a resistance value
dependent on temperature. At the Heating step, if the temperature rise is less than 34°F within 3 minutes a fault occurs. When the fault
is detected, software skips the heating step and continues the program with the next step.
Note: During the first 3 minutes of a heating step, the water temperature is not controlled. The control system waits so that the tem-
perature inside the machine reaches balance.
December 12, 2018
No Water E:02
Possible reasons:
•
Malfunction of water inlet valve
•
No water
•
Insufficient water pressure
•
Cable harness errors
•
Faulty electronics
Heater Fault E:03
Possible reasons:
•
Malfunction of heater
•
Malfunction of NTC (constant NTC resistance)
•
Cable harness errors
•
Faulty electronics
Troubleshooting
Page 31 of 41