Automated Service Test - Viking FDWU324 Service Manual

Hide thumbs Also See for FDWU324:
Table of Contents

Advertisement

Service Procedures
With the door open and "SFT" in the display, press and release the "Start / Pause Pad", as shown below.
Close the dishwasher door and the test will begin, takes approximately 15 minutes, at which time the "END OF CYCLE"
icon will illuminate.
Output
Fill valve + Regeneration
+ Fan
Drain
Fill valve + Fan
Circulation
Circulation + Heater +
3 minutes, 20 seconds
Detergent dispenser
Circulation + Heater
Display flashing "SFt",
Pause
then display "bSL"
Circulation + Regener-
ation
Circulation + Drain
Fault codes will be displayed at end of test.
Page 26 of 41

Automated service test

Condition
Wash Diverter Position
.37 gallons
60 seconds
4.86 gallons
10 seconds
Upper spray arm
1 min, 40 sec (lower arm)
1 min, 40 sec (upper arm)
104° F
Lower spray arm
Lower spray arm
60 seconds
Lower spray arm
30 seconds
Activated (Running)
Motor
RPM's
N/A
0
Fan ON
N/A
0
Drain pump ON
N/A
0
Fan ON
2800
3000
Detergent dispenser should open
3000
For models with intense wash spray arm, this
spray arm should come to it's forward position.
Check the position of the intense wash spray
0
arm, by
THE START BUTTON - CLOSE THE DOOR
AND TEST CONTINUES.
3000
0
Information
OPENING THE DOOR - THEN PRESS
December 12, 2018
Amps
0.20
0.11
0.20
8.42
8.43
8.43
0.00
0.52
0.63