SECTION 3
PERIODIC MAINTENANCE
STORAGE
If the engine will be out of service for approximately
two months or more, use the following storage
procedure:
1. Clean the exterior surfaces of the engine.
2. Change the oil and filter while the engine is still
warm from operation. See "Change Oil and Oil
Filter."
3. The fuel system must be completely emptied, or
the gasoline must be treated with a stabilizer to
prevent deterioration. 1f you choose to use a sta-
bilizer, follow the manufacturers recommenda-
tions, and add the correct amount for the capacity
of the fuel system.
Fill the fuel tank with clean,
fresh gasoline. Run the engine for 2-3 minutes to
get stabilized fuel into the carburetor.
To empty the system, drain the fuel tank and car-
buretor, or run the engine until the tank and system
are empty.
. Remove the spark plugs. Add one tablespoon of
engine oil into each spark plug hole. Install plugs,
but do not connect the plug leads. Crank the en-
gine two or three revolutions.
. Store the engine in a clean, dry place.
3.8