SECTION 9
DISASSEMBLY
DISCONNECT WIRING;
REMOVE RECTIFIER-REGULATOR,
KEY SWITCH, AND SOLENOID
1. Remove the connector from rectifier-regulator.
Remove the lead from center position of connec-
tor. Remove the hex. cap screws and rectifier-
regulator. Refer to Figure 9-9.
fou Blower Housing
Hex Cap a
Screws
:
Miron
8 Rectifier-Regulator R
Figure 9-9. Removing Rectifler-Regulator.
2. Remove the connector trom key switch. Remove
kill lead from connector.
Remove the self-tapping
screws and panel with key switch. Refer to
Figure 9-10.
Keyswitch
ue Panel
Connector
Self-Tapping
Self-Tapping
Screw
|| Screw
Figure 9-10.
Removing Key Switch.
3. Disconnect the leads from starter solenoid. Re-
move the wire tie, self-tapping screws, solenoid
with bracket, and spacer.
Refer to Figure 9-11.
9.4
Selt-Tapping
Screw
Solenoid
g
Screw And Spacer
Figure 9-11.
Removing Starter Solenold.
REMOVE TOP BAFFLE, CYLINDER HEAD
BAFFLES, AND BLOWER HOUSING
1. Remove the self-tapping screws and top baffle.
2. Remove the self-tapping screws and #1 side cyl-
inder head baffle.
3. Remove the self-tapping screws and #2 side cyl-
inder head райе.
4. Remove the self-tapping screws and blower
housing.
REMOVE BREATHER AND VALVE COVER
On #1 Side
1. Remove the hex. nut, copper washer, breather
cover, and gasket.
Refer to Figure 9-12.
Hex Nut And
Copper Washer
Breather Cover
Hex Nut And
Figure 9-12.
Removing Breather and Valve Cover.
2. Remove the filter, seal, breather plate, and gasket.
Refer to Figure 9-13.