1.
Activate Backlights Test
TV Screen for active backlight LEDs.
9
2.
If
No BACKLIGHTS (Series Wired SMPS Panel Connection.)
Plus (+) & Minus (-) pin voltages on the Panel Connector.
9
If no pin voltages replace SMPS.
If voltages exist but no backlight:
The highest pin voltage (
9
Remove Panel connector and measure again to compare.
If the
voltage was high and stays the same high reading a string of Panel LEDs are open. Replace the Panel.
If the
voltage was low and remains low the SMPS is defective.
If the voltage was low and goes high a string of panel LEDs are shorted replace the
BACK LIGHT DIMMING PROBLEMS:
Go to
Menu £ Picture £ Expert £ Backlight and vary level (0 – 20)
If no backlight changes are observed:
Panel Connector pin voltages and
9
If Panel voltages don't change, and BLU_PWM changes, replace
If
BLU_PWM doesn't change replace Main/T-Con Board.
: – Disconnect Lead Cable from Main to Power Supply. CN201
BL Drive Supply)
BLU_PWM voltages CNM803 while changing backlight level.
Panel.
SMPS.