Orv3 compute node amd epyc 9004 - 2ou 2-node up 12-bay e1.s gen4 nvme, orv3 node tray - 2ou 2-node
Table of Contents

Advertisement

Quick Links

TO25-Z11-AA01
ORv3 Compute Node
AMD EPYC™ 9004 - 2OU 2-Node UP 12-Bay E1.S Gen4 NVMe
TO25-BT0
ORv3 Node Tray - 2OU 2-Node
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte TO25-Z11-AA01

  • Page 1 TO25-Z11-AA01 ORv3 Compute Node AMD EPYC™ 9004 - 2OU 2-Node UP 12-Bay E1.S Gen4 NVMe TO25-BT0 ORv3 Node Tray - 2OU 2-Node User Manual Rev. 1.0...
  • Page 2 For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com...
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ...................10 Installation Precautions .................. 10 Product Specifications ..................11 1-2-1 TO25-Z11........................11 1-2-2 TO25-BT0 .......................13 System Block Diagram ................... 14 Chapter 2 System Appearance ..................13 Front View ...................... 13 Rear View ....................... 14 Front Panel LEDs and Buttons ............... 15 RoT LEDs .......................
  • Page 8 Advanced Menu ..................... 44 5-2-1 Trusted Computing ....................46 5-2-2 PSP Firmware Versions ..................47 5-2-3 Legacy Video Select ....................48 5-2-4 AST2600 Super IO Configuration ................49 5-2-5 S5 RTC Wake Settings ...................51 5-2-6 Serial Port Console Redirection ................52 5-2-7 CPU Configuration ....................56 5-2-8 PCI Subsystem Settings ..................57 5-2-9...
  • Page 9 Save & Exit Menu ..................149 5-10 BIOS Recovery .................... 150 5-11 BIOS POST Beep code (AMI standard) ............151 5-11-1 PEI Beep Codes ....................151 5-11-2 DXE Beep Codes ....................151 - 9 -...
  • Page 10: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 11: Product Specifications

    Product Specifications 1-2-1 TO25-Z11 NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System Socket Security Server Operating Properties Š 2OU 2-Node Dimension Š 262.7 (W) x 90 (H) x 740 (D) mm System fan Power Supply Š...
  • Page 12 Expansion Slot Riser Card CRSH01Q: 1 x PCIe x16 (Gen5 x16) low-profile slot Š Riser Card CRSH01R: 1 x PCIe x16 (Gen5 x16) low-profile slot, occupied for E1.S support Š Optional 1 x M.2 slot (CMTP192): M-key Š PCIe Gen4 x4 Š...
  • Page 13: To25-Bt0

    System Š Aspeed® AST2600 management controller Management Š GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š FRU Information Š SEL Log in Linear Storage / Circular Storage Policy Š...
  • Page 14: System Block Diagram

    System Block Diagram 12-Channel DDR5, 12 x DIMMs Speed up to 4800 MHz 12-bay 9.5mm E1.S NVMe 4 x MCIO AMD EPYC™ 9004 PCIe4.0 x16 Socket SP5 PCIe4.0 x16 PCIe5.0 x16 CMTP192 (optional) OCP 3.0 PCIe4.0 x4 Riser Card CRSH01Q PCIe5.0 x16 PCIe 5.0 x16 LP slot USB2.0 x1...
  • Page 15: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View SLOT2 SLOT1 Description EDSFF E1.S SSD Bay Front Panel LEDs and Buttons 2 x USB 3.2 Gen1 VGA Port Server Management LAN Port OCP 3.0 Slot (SFF) PCIe Card Slot • Refer to section 2-3 Front Panel LEDs and Buttons for a detailed description of the function of the LEDs.
  • Page 16: Rear View

    Rear View Description Power Distribution Board to Bus Bar Connector System Appearance - 14 -...
  • Page 17: Front Panel Leds And Buttons

    Front Panel LEDs and Buttons No. Name Color Status Description Green Indicates the system is powered on. Power button Green Blink System is in ACPI S1 state (sleep mode). with LED - System is not powered on or in ACPI S5 state (power off) - System is in ACPI S4 state (hibernate mode) Blue Indicates the system identification is active.
  • Page 18: Rot Leds

    RoT LEDs LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images Blinks Blue Blinks Green Recovering BMC Active Flash 4 times per second 4 times per second Blinks Blue...
  • Page 19 Blinks Blue Blinks Amber BIOS : AUTH fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Green 2 times per second 2 times per second BMC : AUTH fail after doing recovery (Note3) [ON OFF OFF] [ON OFF OFF] Blinks Blue Blinks Amber...
  • Page 20: Front System Lan Leds

    Front System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green 1GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 21: Storage Leds

    Storage LEDs NVMe HDD Present RAID SKU Color Locate Rebuilding HDD Access Fault (No Access) No RAID NVMe LED configuration (On NVMe Amber ON(*1) (via HBA) Module) RAID configuration (via HW RAID NVMe LED Amber BLINK Alternately Card or SW RAID Card) NOTE: *1: Depends on HBA/Utility Spec.
  • Page 22: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 23: Removing Shelf From The Rack

    Removing Shelf from the Rack Before you remove or install the computing node: • Remove the computing node before removing the shelf. Follow these instructions to remove the Shelf from the rack: Press the release latches inward while simultaneously pulling the handle for the shelf. Pull the shelf out of the cabinet.
  • Page 24: Removing Computing Node From The Shelf

    Removing Computing Node from the Shelf Follow these instructions to remove a computing node from the shelf: Press the retaining clip on the right side of the computing node in the direction indicated. Pull out the computing using the handle. Insert the replacement computing node.
  • Page 25: Installing The Edsff Ssd

    Installing the EDSFF SSD Read the following guidelines before you begin to install the EDSFF SSD: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if it is inserted incorrectly. •...
  • Page 26: Removing And Installing The Fan Duct

    Removing and installing the Fan Duct Follow these instructions to remove the Fan Duct: Remove the two screws securing the fan duct. Lift up to remove the fan duct. To reinstall the fan duct, align the fan duct with the guiding groove. Push down the fan duct into chassis until its firmly seats, then install the four screws to secure the fan ducts in place.
  • Page 27 Follow these instructions to reinstall the Fan Duct: Align the fan duct with the guiding groove. Push down the fan duct until it is firmly seated on the system. System Hardware Installation - 23 -...
  • Page 28: Openning And Closing The Hard Drive Upper Tray

    Openning and closing the Hard Drive Upper Tray Read the following guidelines before you begin to install the Hard Drive Upper Tray: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if inserted incorrectly. •...
  • Page 29 Follow these instructions to close the Hard Disk Drive Upper Tray: Pull the release latch on the side to unlock the Upper tray. Flip over the Upper Tray. System Hardware Installation - 25 -...
  • Page 30: Installing The Cpu And Heat Sink

    Installing the CPU and Heat Sink Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 31 • To install/remove the Intel heatsink use a T30-Lobe screwdriver or drill bit with a screw torque of 8.0 +/- 0.5kgf*cm • Please refer to the Heatsink Label for the screw tightening torque value. System Hardware Installation - 27 -...
  • Page 32: Installing Memory

    Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 33: Removing And Installing The Memory

    3-7-2 Removing and Installing the Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on to this motherboard.
  • Page 34: Processor And Memory Module Matrix Table

    3-7-3 Processor and Memory Module Matrix Table Memory Q’ty CPU0 for each CPU G0 H0 I0 J0 K0 L0 D0 C0 1 DIMM 2 DIMM 4 DIMM 6 DIMM 8 DIMM 10 DIMM 12 DIMM 3-7-4 Memory Population Table EPYC Memory Speed based on DIMM Population (One DIMM per Channel) DIMM Population DIMM Max EPYC 9004...
  • Page 35: Installing The Pci Expansion Card

    Installing the PCI Expansion Card • The PCI riser assembly does not include a riser card or any cabling as standard. To install a PCI card, a riser card must be installed. Follow these instructions to install the left PCI Expansion card: To open the upper tray.( See Section 3-3) Remove the screw securing the riser bracket to the system.
  • Page 36: Installing The Mezzanine Card

    Installing the Mezzanine Card 3-9-1 Installing the OCP 3.0 Mezzanine Card Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with pull tab • OCP 3.0 SFF with ejector latch Follow these instructions to install an OCP 3.0 Mezzanine card: Remove the two screws securing the OCP 3.0 card slot cover.
  • Page 37: Replacing The Fan Assembly

    3-10 Replacing the Fan Assembly Follow these instructions to replace the fan assembly: Press the release latches on the bottom-left and top-right sides of the fan assembly inwards while pulling the fan out of its compartment To install the replacement fan assembly, push the assembly into the compartment. System Hardware Installation - 33 -...
  • Page 38: Cable Routing

    3-11 Cable Routing MotherBorad Power Distribu on Borad Bus Bar Top Storage Borad#1 E1S0 E1S1 E1S2 E1S3 E1S4 E1S5 E1S6 E1S7 Top Storage Borad#2 Bo om Storage Borad Re-driver card (CORC211) E1S8 E1S9 E1S10 E1S11 Front Board: BP_1 Front Panel LEDs and Buttons Cable Power Distribution Board: FP_1 Power Distribution Board: BP_PWR1 Storage Board Power Cable...
  • Page 39 Power Distribution Board: MCIO_A2 MCIO Cable Bottom Storage Board: C15-3 Bottom Storage Board: C15-2 Power Distribution Board: MCIO_A1 MCIO Cable Bottom Storage Board: C15-1 Bottom Storage Board: C15-0 Power Distribution Board: MCIO_B2 MCIO Cable Top Storage Board#2: C15-3 Top Storage Board#2: C15-2 Power Distribution Board: MCIO_B1 MCIO Cable Top Storage Board#2: C15-1...
  • Page 40: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components Item Description Item Description BMC Readiness LED SlimSAS Connector (SATA0/SATA Signal) Proprietary PCIe Slot SGPIO Connector (SGPB) (Gen 5/x16 slot/GENZ_2) BMC Flash ROM #1 SGPIO Connector (SGPA) BMC Flash ROM #2 BIOS Flash ROM #1 OCP 3.0 Connector (PCIe Gen5 x16) BIOS Flash ROM #2 Proprietary PCIe Slot...
  • Page 41: Jumper Setting

    Jumper Setting Clear CMOS CLR_CMOS Enable Default HOST_SMBUS_SEL BIOS defined Reserved BIOS_PWD Clear supervisor password Normal [Default] BIOS_RCVR BIOS recovery mode Normal [Default] Motherboard Components - 38 -...
  • Page 42: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 43  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 44: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 45 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version Displays BMC firmware version information.
  • Page 46 Parameter Description System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. BIOS Setup - 43 -...
  • Page 47: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. When Boot Mode Select is set to UEFI (Default) BIOS Setup - 44 -...
  • Page 48 When "Boot Mode Select" is set to Legacy in the Boot > Boot Mode Select section BIOS Setup - 45 -...
  • Page 49: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be Security Device Support available. Options available: Disable, Enable. Default setting is Enable. Select Enable to activate TPM support feature. SPI TPM Support Options available: Disabled, Enabled.
  • Page 50 5-2-2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window are non-configurable. BIOS Setup - 47 -...
  • Page 51: Legacy Video Select

    5-2-3 Legacy Video Select Description Parameter Selects between onboard or external VGA support. OnBrd/Ext VGA Select Options available: Auto, Onboard, External. Default setting is Auto. This configurable option will be displayed when "Boot Mode Select" is set to Legacy in the Boot > (Note) Boot Mode Select section.
  • Page 52: Ast2600 Super Io Configuration

    5-2-4 AST2600 Super IO Configuration Description Parameter AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Press [Enter] for configuration of advanced items. Configuration BIOS Setup - 49 -...
  • Page 53 5-2-4-1 Serial Port 1 Configuration Description Parameter Serial Port 1 Configuration Enable/Disable the Serial Port (COM). When set to Enabled allows you to configure the Serial port 1 settings. When set to Disabled, displays no Serial Port (Note) configuration for the serial port. Options available: Disabled, Enabled.
  • Page 54: S5 Rtc Wake Settings

    5-2-5 S5 RTC Wake Settings Parameter Description Enable/Disable system wake on alarm event. Options available: Disabled, Fixed Time, Dynamic Time. When Fixed Time Wake System from S5 is selected, system will wake on the hr::min::sec specified. Default setting is Disabled. BIOS Setup - 51 -...
  • Page 55: Serial Port Console Redirection

    5-2-6 Serial Port Console Redirection Parameter Description Select whether to enable console redirection for specified device. Console COM1/Serial Over LAN redirection enables the users to manage the system from a remote Console Redirection (Note) location. Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items.
  • Page 56 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 57 Parameter Description Legacy Console Redirection Press [Enter] to configure advanced items. Redirection COM Port Š – Selects a COM port for Legacy serial redirection. – Default setting is COM1/SOL. Resolution Š – Selects the number of rows and columns used in Console Redirection for legacy OS support.
  • Page 58 Parameter Description Flow Control Š – Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are full, a 'stop' signal can Serial Port for Out-of-Band be sent to stop the data flow. Once the buffers are empty, a 'start' EMS Console Redirection signal can be sent to re-start the flow.
  • Page 59: Cpu Configuration

    5-2-7 CPU Configuration Description Parameter Enable/Disable the CPU Virtualization. SVM Mode Options available: Disabled, Enabled. Default setting is Enabled. Press [Enter] to view the memory information related to CPU 0/1. CPU 0 Information BIOS Setup - 56 -...
  • Page 60 5-2-8 PCI Subsystem Settings BIOS Setup - 57 -...
  • Page 61 Description Parameter Displays the PCI Bus Driver version information. PCI Bus Driver Version MCIO#_Lanes Configuration Change the PCIe lanes. (Note1) GEN_#_Lanes Configuration Options available: Disabled, Auto, x16, x8x8, x8x4x4, x4x4x8, (Note2) x4x4x4x4. Default setting is Auto. OCP Lanes Configuration (Note3) MCIO#_I/O ROM When enabled, this setting will initialize the device expansion ROM (Note1)
  • Page 62: Usb Configuration

    5-2-9 USB Configuration Parameter Description USB Configuration USB Module Version Displays the USB module version information. USB Controllers Displays the supported USB controllers. USB Devices: Displays the USB devices connected to the system. Enable/Disable the Legacy USB support function. AUTO option disables legacy support if no USB devices are connected.
  • Page 63 Parameter Description Selects the time-out value during a USB mass storage device reset. Device reset time-out Options available: 10 sec, 20 sec, 30 sec, 40 sec. Default setting is 20 sec. Maximum time the device will take before it properly reports itself to the Host Controller.
  • Page 64: Network Stack Configuration

    5-2-10 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support Options available: Enabled, Disabled.
  • Page 65: Post Report Configuration

    5-2-11 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 62 -...
  • Page 66: Nvme Configuration

    5-2-12 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. Enable/Disable NVMe LED Control. NVMe LED Control Options available: System Default, Disabled, Enabled. Default setting is Enabled. BIOS Setup - 63 -...
  • Page 67: Sata Configuration

    5-2-13 SATA Configuration Parameter Description Displays the installed HDD devices information. System will automatically SATA Configuration detect HDD type. BIOS Setup - 64 -...
  • Page 68: Graphic Output Configuration

    5-2-14 Graphic Output Configuration Parameter Description Selects output device type. Output Device Type Options available: First loaded Device, Onboard Device, External Device, Specific Device. Default setting is Onboard Device. BIOS Setup - 65 -...
  • Page 69: Amd Mem Configuration Status

    5-2-15 AMD Mem Configuration Status Description Parameter Press [Enter] to view the memory configuration status related to CPU 0/1. CPU 0 BIOS Setup - 66 -...
  • Page 70: Tls Auth Configuration

    5-2-16 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 71: Ram Disk Configuration

    5-2-17 RAM Disk Configuration Parameter Description Specifies the type of memory to use from available memory pool in system to create a disk. Disk Memory Type Options available: Boot Service Data, Reserved. Default setting is Boot Service Data. Creates a raw RAM disk. Size (Hex) Š...
  • Page 72: Iscsi Configuration

    5-2-18 iSCSI Configuration Parameter Description Press [Enter] and name iSCSI Initiator. Only IQN format is accepted. iSCSI Initiator Name Range: from 4 to 223 Add an Attempt Press [Enter] to configure advanced items. Delete Attempts Press [Enter] to configure advanced items. Change Attempt Order Press [Enter] to configure advanced items.
  • Page 73 Description Parameter Support RDMA Š – Enable/Disable RDMA support for this port. – Options available: Disabled, Enabled. Default setting is Disabled. DCB Protocol Š – Enable/Disable DCB protocol. – Options available: Disabled, Enabled (IEEE only), CEE (only), Both (IEEE preferred with fallback to CEE). Default setting is Disabled. LLDP nearest bridge Š...
  • Page 74 Parameter Description Pre-boot Wake On LAN Š – Configures Pre-boot Wake on LAN (WOL). – Options available: Disabled, Enabled. Default setting is Enabled. VLAN Mode Š – Configures the virtual LAN (VLAN) mode. – Options available: Disabled, Enabled. Default setting is Disabled. MBA Configuration Menu VLAN ID Š...
  • Page 75: Amd Cbs Menu

    AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU-related information that the BIOS automatically sets. Select a submenu item, then press [Enter] to access the related submenu screen. BIOS Setup - 72 -...
  • Page 76 5-3-1 CPU Common Options BIOS Setup - 73 -...
  • Page 77: Cpu Common Options

    Parameter Description CPU Common Options Performance Press [Enter] for configuration of advanced items. Allow REP-MOV/STOS to use non-caching streaming stores for large sizes. REP-MOV/STOS Streaming Options available: Disabled, Enabled. Default setting is Enabled. Prefetcher settings Press [Enter] for configuration of advanced items. Core Watchdog Press [Enter] for configuration of advanced items.
  • Page 78 Parameter Description Enabled: Enter system memory is covered. SNP Memory (RMP Table) Options available: Disabled, Enabled, Custom, Auto. Coverage Default setting is Auto. Controls the Secure Memory Encryption Enable (SMEE) function. SMEE Options available: Disable, Enable, Auto. Default setting is Auto. Action to take when a CCD BIST failure is detected.
  • Page 79 5-3-1-1 Performance Parameter Description Performance Options available: Normal Operation, Customized. Default setting is Normal OC Mode (Note) Operation. Allows you to accept or decline enabling Custom Core Pstates. When Custom Core Pstates accepted, you can disable or customize core pstates. Allows you to accept or decline enabling CCDs, processor cores and threads.
  • Page 80 5-3-1-2 Prefetcher Settings Parameter Description Prefetcher settings Enable/Disable L1 Stream HW Prefetcher. L1 Stream HW Prefetcher Options available: Disable, Enable, Auto. Default setting is Auto. Use memory access history of individual instructions to fetch additional lines when each access is a constant distance from the previous. L1 Stride Prefetcher Enable/Disable L1 Stride Prefetcher.
  • Page 81 5-3-1-3 Core Watchdog Parameter Description Core Watchdog Enable/Disable CPU Watchdog Timer. Core Watchdog Timer Enable (Note) Options available: Disabled, Enabled, Auto. Default setting is Auto. Select the CPU Watchdog Timer interval. Options available: 2.681s, 1.340s, 669.41ms, 334.05ms, 166.37ms, Core Watchdog Timer Interval 82.53ms, 40.61ms, 20.970ms, 10.484ms,5.241ms, 2.620ms, 1.309ms, 654.08us, 326.4us, 162.56us, 80.64us, 39.68us, Auto.
  • Page 82: Df Common Options

    5-3-2 DF Common Options Parameter Description DF Common Options Memory Addressing Press [Enter] for configuration of advanced items. ACPI Press [Enter] for configuration of advanced items. Link Press [Enter] for configuration of advanced items. SDCI Press [Enter] for configuration of advanced items. Probe Filter Press [Enter] for configuration of advanced items.
  • Page 83 5-3-2-1 Memory Addressing Parameter Description Memory Addressing Specifies the number of desired NUMA nodes per socket. Options available: NPS0,NPS1,NPS2,NPS4, Auto. Default setting is Auto. NUMA nodes per socket NOTE! • Available options may vary by system configuration. • Only dual processor configuration supports NPS0. Enable/Disable the Memory interleaving feature.
  • Page 84 5-3-2-2 ACPI Parameter Description ACPI ACPI SRAT L3 Cache As Enable/Disable report each L3 cache as a NUMA Domain to the OS. Options available: Disabled, Enabled, Auto. Default setting is Auto. NUMA Domain Determines how the SLIT distances are declared. ACPI SLIT Distance Control Options available: Manual, Auto.
  • Page 85 5-3-2-3 Link Parameter Description Enable/Disable GMI link encryption. GMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable xGMI link encryption. xGMI encryption control Options available: Disabled, Enabled, Auto. Default setting is Auto. Configures the number of xGMI2 links used on a multi-socket system. xGMI Link Configuration Options available: Auto, 3 xGMI Links, 4 xGMI Links.
  • Page 86 Parameter Description xGMI Global Preset List Press [Enter] to configure the xGMI Preset list. xGMI Initial Preset Press [Enter] to configure the xGMI Initial Preset CPU0/1 link. xGMI TXEQ Search Mask Press [Enter] to configure the xGMI TXEQ Search Mask CPU0/1 link. Press [Enter] to configure the xGMI AC/DC Coupled link.
  • Page 87 5-3-2-4 SDCI Parameter Description Options available: Disabled, Enabled, Auto. Default setting is Auto. SDCI (Note) DisRmSteer Options available: Disabled, Enabled, Auto. Default setting is Auto. (Note) Advanced items prompt when this item is defined. BIOS Setup - 84 -...
  • Page 88 5-3-2-5 Probe Filter Parameter Description Specifies whether multiple memory/CXL channels will share probe filter storage. For memory sizes of 16TB or larger, this features is ignored as it is Organization auto-selected to 'shared'. Options available: Disabled, Shared, Auto. Default setting is Auto. Controls PDR settings that may impact performance by workload and/or processor.
  • Page 89: Umc Common Options

    5-3-3 UMC Common Options Parameter Description UMC Common Options DDR Addressing Options Press [Enter] for configuration of advanced items. DDR Controller Configuration Press [Enter] for configuration of advanced items. DDR MBIST Options Press [Enter] for configuration of advanced items. DDR RAS Press [Enter] for configuration of advanced items.
  • Page 90 5-3-3-1 DDR Addressing Options Parameter Description DDR Addressing Options Interleaves memory blocks across the DRAM chip selects for node 0. Chipselect Interleaving Options available: Disabled, Auto. Default setting is Auto. Enable or disable bank addressing hashing. Address Hash Bank Options available: Enabled, Disabled, Auto. Default setting is Auto. Enable or disable CS addressing hashing.
  • Page 91 5-3-3-2 DDR Controller Configuration Parameter Description DDR Cotroller Configuration DDR Power Options Press [Enter] for configuration of advanced items. Memory Channel Diable Press [Enter] for configuration of advanced items. Refresh Management (RFM) Press [Enter] for configuration of advanced items. BIOS Setup - 88 -...
  • Page 92 5-3-3-2-1 DDR Power Options Parameter Description DDR Power Options Enable or disable DDR power down mode. Power Down Enable Options available: Enabled, Disabled, Auto. Default setting is Auto. Sub Urgent Refresh Lower Specifies the stored refresh limit required to enter sub-urgent refresh mode. Bound Urgent Refresh Limit Specifies the stored refresh limit required to enter urgent refresh mode.
  • Page 93 5-3-3-2-2 Memory Channel Disable Parameter Description Memory Channel Disable Memory Channel Disable Bitmask CPU0 Channel_# Press [Enter] to enable/disable specific memory channel. BIOS Setup - 90 -...
  • Page 94 5-3-3-2-3 Refresh Management (RFM) Parameter Description Refresh Management (RFM) Configure Refresh Management. Refresh Management Options available: Enable, Disable, Auto, Force Enable. Default setting is Auto. RAA Initial Management Override Rolling Accumulated ACT Initial Management Threshold. Threshold Options available: 32, 40, 48, 56, 64, 72, 80, Auto. Default setting is Auto. RAA Maximum Management Override Rolling Accumulated ACT Maximum Management Threshold.
  • Page 95 5-3-3-3 DDR MBIST Options Parameter Description DDR MBIST Options Enable/Disable the Memory MBIST function. MBIST Enable Options available: Enabled/Disabled. Default setting is Disabled. Selects MBIST Test Mode. Interface Mode: Tests Single and Multiple CS transactions and Basic Connectivity. MBIST Test Mode (Note1) Data Eye Mode: Measures Voltage vs.
  • Page 96 Parameter Description For DRAM errors found in the BIOS memory BIST select tje repair type. PMU Mem BIST Algprithm Options available: Soft, Repair, Hard Repair, No Rrepairs -Test only.. DDR Healing BIST (Note2) Default setting is Soft Repair. BIOS Setup - 93 -...
  • Page 97 5-3-3-3-1 Data Eye Parameter Description Data Eye Pattern Select Options available: PRBS, SSO, Both. Default setting is PRBS. Pattern Length Determines the pattern length. The possible options are N=3..12. This item helps read the aggressors channels. Aggressor Channel Options available: Disabled, 1 Aggressor Channel, 3 Aggressor Channels, 7 Aggressor Channels.
  • Page 98 Parameter Description Target Static Lane Select This item is configurable when Target Static Lane Control is set to Upper 32 bits Enabled. Target Static Lane Select This item is configurable when Target Static Lane Control is set to Lower 32 bits Enabled.
  • Page 99 5-3-3-4 DDR RAS Parameter Description DDR RAS Enable/Disable the Data Poisoning function. Data Poisoning Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the DRAM Boot Package Repair function. DRAM Boot Time Package Repair Options available: Enable/Disable. Default setting is Disable. DRAM Runtime Post Package Enable/Disable the DRAM Runtime Post Package Repair function.
  • Page 100 Parameter Description Press [Enter] to configure advanced items. DRAM ECC Symbol Size Š – Configures the DRAM ECC Symbol Size. – Options available: Auto, x4, x8, x16. Default setting is Auto. DRAM ECC Enable Š – Enable/Disable DRAM ECC. When set to Auto, it will set ECC to enable.
  • Page 101 Press [Enter] to configure advanced items. DRAM ECS Mode Š – Options available: Auto, AutoECS, Manual1EECS, DisableECS. Default setting is Auto. DRAM Redirect Scrubber Enable Š – Options available: Auto, Enabled, Disabled. Default setting is Auto. DRAM Scrub Redirection Limit Š...
  • Page 102 5-3-3-5 DDR Bus Configuration Parameter Description DDR Bus Configuration Select the DRAMs On-die Termination impedance for RTT_NOM_WR. Dram ODT impedance RTT_ Options available: Auto, RTT_OFF, RZQ (240), RZQ/2 (120), RZQ/3 (80) NOM_WR RZQ/4 (60), RZQ5/(40), RZQ6/(20), RZQ7/(34). Default setting is Auto. Select the DRAMs On-die Termination impedance for RTT_NOM_RD.
  • Page 103 Parameter Description Select the ODT impedance for all DBYTE IOs. Options available: Auto, High Impedance, 480 ohm, 240 ohm, 160 ohm, Processor ODT impedance 120 ohm, 96 ohm, 80 ohm, 68.6 ohm, 60 ohm, 53.3 ohm,48 ohm, 43.6 ohm, 40 ohm, 36.9 ohm, 34.3 ohm, 32 ohm, 30 ohm, 28.2 ohm, 26.7 ohm, 25.3 ohm.
  • Page 104 5-3-3-6 Enforce POR Parameter Description DDR Training Options Press [Enter] to configure the Plan of Record (POR) to enable / disable Enforce POR restrictions for DDR5 frequency and voltage programming. Memory speeds will be capped at AMD guidelines. BIOS Setup - 101 -...
  • Page 105 5-3-3-7 DDR Training Options Parameter Description DDR Training Options Specify PDA enumeration mode. DRAM PDA Enumerate ID Options available: Auto, Toggling PDA enumeration mode, Legacy PDA Programming enumeration mode. Default setting is Auto. BIOS Setup - 102 -...
  • Page 106 5-3-3-8 DDR Security Parameter Description Security Enable/Disable Transparent SME. TSME Options available: Auto, Enabled, Disabled. Default setting is Auto. Options available: AES-128, AES-256. Default setting is AES-256. Enable/Disable Data Scrambling. Data Scramble Options available: Enabled, Disabled. Default setting is Enabled. SME-MK Options available: Enabled, Disabled.
  • Page 107 5-3-3-9 DDR PMIC Configuration Parameter Description DDR PMIC Configuration Enables support for PMIC Error Reporting. PMIC Error Reporting Options available: Auto, False, True. Default setting is Auto. Options available: Secure Mode, Programming Mode. PMIC Operation Mode Default setting is Programming Mode. PMIC Fault Recovery Options available: Always, Never, Once.
  • Page 108 5-3-3-10 DDR Miscellaneous Parameter Description DDR Miscellaneous DRAM Survives Warm Reset Options available: Enabled, Disabled. Default setting is Enabled. ODTS CMD Throttle Threshold Options available: Auto, 85'C, 90'C, 95'C. Default setting is Auto. BIOS Setup - 105 -...
  • Page 109 5-3-3-11 DDR PHY (CMN) Parameter Description DDR PHY (CMN) Options available: Auto, Enabled, Disabled. Default setting is Auto. Periodic Training BIOS Setup - 106 -...
  • Page 110 5-3-4 NBIO Common Options BIOS Setup - 107 -...
  • Page 111: Nbio Common Options

    Parameter Description NBIO Common Options Enable/Disable the IOMMU function. IOMMU Options available: Disabled, Enabled. Default setting is Enabled. Enable/Disable DMAr system protection during POST. DMAr Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable DMA remap support in IVRS IVinfo Field. DMA Protection Options available: Auto, Enabled, Disabled.
  • Page 112 Parameter Description Enable/Disable the data link feature capability. Data Link Feature Cap Options available: Enabled, Disabled, Auto. Default setting is Auto. Enable/Disable the running PCIE CV tool support. CV test Options available: Auto, Enabled, Disabled. Default setting is Auto. Enable/Disable the SEV-SNP support. SEV-SNP Support Options available: Disable, Enable.
  • Page 113 5-3-4-1 SMU Common Options Parameter Description SMU Common Options TDP Control Options available: Manual, Auto. Default setting is Auto. PPT Control Options available: Manual, Auto. Default setting is Auto. Selects use the fused Determinism or set customized Determinism. Determinism Control Options available: Manual, Auto.
  • Page 114 Parameter Description CPPC Preferred Cores Options available: Disabled, Enabled, Auto. Default setting is Auto. Enable/Disable the HSMP support. HSMP Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SVI3 SVC Speed Control Options available: Auto, Manual. Default setting is Auto. Options available: Auto, Disable, 1 stack, 2 stack, 4 stack.
  • Page 115 5-3-4-2 NBIO RAS Common Options Parameter Description NBIO RAS Common Options NBIO RAS Control Options available: Disabled, MCA, Auto. Default setting is Auto. Configures the Egress Poison High Severity. Each bit set to 1 enables Egress Poison Severity High High severity on the associated IOHC egress port. A bit of 0 indicates LOW severity.
  • Page 116 Parameter Description Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask High arrays. Uncorrected Converted to Enables mask for masking of uncorrectable parity errors on internal Poison Enable Mask Low arrays. Specifies the timer interval of the SYSHUB Watchdog timer in System Hub Watchdog Timer milliseconds.
  • Page 117 5-3-4-3 nBif Common Options Parameter Description SRIOV Š – Options available: Auto, Disable, Enable. Default setting is Auto. Š – Options available: Auto/Default, Disable, Enable. Default setting is Auto/Default. Š – Options available: Auto, Disable, Enable. Default setting is Auto. Š...
  • Page 118 Parameter Description ACS Rcc_Dev0 Š – Options available: Auto, Disable, Enable. Default setting is Auto. AER Rcc_Dev0 Š – Options available: Auto, Disable, Enable. Default setting is Auto. DlfEnableStrap1 Š – Options available: Auto, Disable, Enable. Default setting is Auto. Phy16GTStrap1 Š...
  • Page 119 Parameter Description RCC_DEV0 EXTENDED_FMT Š (continued) – Options available: Auto, Disable, Enable. Default setting is Auto. BIOS Setup - 116 -...
  • Page 120 5-3-4-4 Link EQ Present Options Parameter Description Link EQ Present Options Press [Enter] for configuration of advanced items. GEN3 Present Search Mask Configuration Š – Options available: Auto, Custom, Enable. Default setting is Auto. Press [Enter] for configuration of advanced items. GEN4 Present Search Mask Configuration Š...
  • Page 121: Fch Common Options

    5-3-5 FCH Common Options Parameter Description FCH Common Options I3C/I2C Configuration Options Press [Enter] for configuration of advanced items. SATA Configuration Options Press [Enter] for configuration of advanced items. USB Configuration Options Press [Enter] for configuration of advanced items. AC Power Loss Options Press [Enter] for configuration of advanced items.
  • Page 122 5-3-5-1 I3C/I2C Configuration Options Parameter Description I3C/I2C Configuration Options Options available: Both Disabled, I3C Enabled, I2C Enabled, Auto. I3C/I2C 0/1/2/3 Enable Default setting is Auto. I2C 4/5 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. Release SPD Host Control Options available: Disabled, Enabled, Auto.
  • Page 123 5-3-5-2 SATA Configuration Options Parameter Description SATA Configuration Options Enable/Disable OnChip SATA controller. SATA Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Staggered Spin-up Options available: Disabled, Enabled, Auto. Default setting is Auto. SATA Disabled AHCI Prefetch Options available: Disabled, Enabled, Auto.
  • Page 124 5-3-5-3 USB Configuration Options Parameter Description USB Configuration Options Enable/Disable USB controller. XHCI Controller0/1 enable Options available: Enabled, Disabled, Auto. Default setting is Auto. USB ecc SMI Enable Options available: Enable, Off, Auto. Default setting is Auto. Press [Enter] for configuration of advanced items. MCM USB enable XHCI2/ XHCI3 enable (Socket1) Š...
  • Page 125 5-3-5-4 AC Power Loss Options Parameter Description AC Power Loss Options Selects the AC Loss Control Method. AC Loss Control Options available: Power Off, Power On, Last State. Default setting is Last State. BIOS Setup - 122 -...
  • Page 126 5-3-5-5 Uart Configuration Options Parameter Description Uart Configuration Options Uart 0/1/2/3 Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 123 -...
  • Page 127 5-3-5-6 ESPI Configuration Options Parameter Description ESPI Configuration Options ESPI Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 124 -...
  • Page 128 5-3-5-7 FCH RAS Options Parameter Description FCH RAS Options Enable/Disable the ALink RAS Support. ALink RAS Support Options available: Disabled, Enabled, Auto. Default setting is Auto. Enables AB to forward downstream sync-flood message to system Reset After Sync Flood controller. Options available: Enable, Disable, Auto.
  • Page 129 5-3-5-8 Miscellaneous Options Parameter Description Miscellaneous Options Enable/Disable Boot Timer. Boot Timer Enable Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 126 -...
  • Page 130: Soc Miscellaneous Control

    5-3-6 SOC Miscellaneous Control Parameter Description SOC Miscellaneous Control Enable/Disable the ConsoleOut function for ABL. ABL Console Out Control (Note) Options available: Disable, Enable, Auto. Default setting is Auto. ABL Console Out Serial Options available: eSPI, SOC UART0, SOC UART1, Auto. Default setting is Auto.
  • Page 131 Press [Enter] for configuration of advanced items. FAR enforcement state Š – Default setting is Enabled. Firmware Anti-rollback (FAR) SPL value in the CPU Fuse Š SPL value in the SPL table Š FAR Switch Š – Options available: Disabled, Enabled, Auto. Default setting is Auto. BIOS Setup - 128 -...
  • Page 132: Cxl Common Options

    5-3-7 CXL Common Options Parameter Description CXL Common Options Options available: Auto, Enabled, Disabled. Default setting is Auto. CXL Control Options available: Auto, Enabled, Disabled. Default setting is Auto. CXL SPM CXL Encryption Options available: Enabled, Disabled. Default setting is Disabled. Options available: Auto, Enabled, Disabled.
  • Page 133: Amd Pbs Menu

    AMD PBS Menu AMD PBS Option menu displays submenu options for configuring the function of AMD PBS. Select a submenu item, then press [Enter] to access the related submenu screen. Parameter Description Press [Enter] for configuration of advanced items. Enable/Disable SPI Locking for protect ROM part. SPI Locking Options available: Disabled, Enabled.
  • Page 134: Ras

    5-4-1 RAS Parameter Description Enable/Disable the Periodic SMI for polling [MCA Threshold] error. RAS Periodic SMI Control Options available: Disabled, Enabled. Default setting is Enabled. SMI Threshold Configures the SMI Threshold value. SMI Scale Configures the SMI Scale value. Defines the unit of time scale. SMI Scale Unit Options available: millisecond, second, minute.
  • Page 135 Parameter Description PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Mask register of Root Port. Mask Reg PCIe Root Port UnCorr Err Initialize the PCIe AER Uncorrected Error Severity register of Root Port. Sev Reg PCIe Device Corr Err Mask Initialize the PCIe AER Corrected Error Mask register of PCIe device.
  • Page 136: Cxl Range Encryption

    5-4-2 CXL Range Encryption Parameter Description Range_# Enter memory base address and limit address. Range_# Memory Base Start CXL Range Encryption Start to encrypt all memory ranges. BIOS Setup - 133 -...
  • Page 137: Chipset Setup Menu

    Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of the North Bridge. Select a submenu item, then press <Enter> to access the related submenu screen. Parameter Description PCIe Link Training Type Options available: 1 Step, 2 Step. Default setting is 1 Step. Options available: Off, On.
  • Page 138: North Bridge

    5-5-1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information. CPU 0 Information Press [Enter] to view information related to CPU 0/1. BIOS Setup - 135 -...
  • Page 139 5-5-2 Fabric Resource BIOS Setup - 136 -...
  • Page 140: Fabric Resource

    Parameter Description Fabric Resource CPU 0/1 NBIO_# PCIe Bus Change CPU 0/1 NBIO_# PCIe Bus Number. Number Change CPU 0/1 NBIO_# Prefetchable MMIO Above 4G Size. Prefetchable Mmio Above 4G Options available: System Default, 0, 1G, 2G, 4G, 8G, 16G, 32G, 64G, size 128G, 256G, 512G, 1T, 2T, 4T, 8T.
  • Page 141: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Default setting is Enabled. Configures the FRB2 Timer timeout. FRB-2 Timer Options available: 3 minutes, 4 minutes, 5 minutes, 6 minutes. Default setting is 6 timeout minutes. Configures the FRB2 Timer policy. FRB-2 Timer Policy Options available: Do Nothing, Reset, Power Down, Power Cycle.
  • Page 142 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC network Press [Enter] to configure advanced items. configuration IPv6 BMC Network Press [Enter] to configure advanced items. Configuration BIOS Setup - 139 -...
  • Page 143: System Event Log

    5-6-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Disabled, Enabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Erase SEL Options available: No/Yes, On next reset/Yes, On every reset.
  • Page 144 5-6-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 141 -...
  • Page 145: Bmc Network Configuration

    5-6-3 BMC Network Configuration Parameter Description BMC network configuration Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters Configuration Address source during BIOS phase. Options available: Unspecified, Static, DynamicBmcDhcp. Default setting is DynamicBmcDhcp.
  • Page 146: Ipv6 Bmc Network Configuration

    5-6-4 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 147: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 148: Secure Boot

    5-7-1 Secure Boot The Secure Boot feature is applicable if supported by your Operating System.If your Operating System is not supporting Secure Boot, the system will hang when starting the Operating System. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function.
  • Page 149 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 150: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 151 Parameter Description Selects the boot mode. Boot mode select Options available: LEGACY, UEFI. Default setting is UEFI. FIXED BOOT ORDER Priorities Press [Enter] to configure the boot priority. By default, the server searches for boot devices in the following sequence: Boot Option #1 / #2 / #3 / #4 / Hard drive.
  • Page 152: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save Changes and Exit Options available: Yes, No.
  • Page 153: Bios Recovery

    5-10 BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
  • Page 154: Bios Post Beep Code (Ami Standard)

    5-11 BIOS POST Beep code (AMI standard) 5-11-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...