Summary of Contents for Gigabyte G291-2G0
Page 1
G291-2G0 Dual LGA3647 sockets motherboard for Intel Xeon Scalable Family processors ® ® Service Guide Rev. 1.0...
Page 2
GIGABYTE's prior written permission. Documentation Classifications In order to assist in the use of this product, GIGABYTE provides the following types of documentations: For detailed product information, carefully read the User's Manual.
Page 3
Conventions The following conventions are used in this user's guide: NOTE! Gives bits and pieces of additional information related to the current topic. CAUTION! Gives precautionary measures to avoid possible hardware or software problems. WARNING! Alerts you to any damage that might result from doing or not doing specific actions.
Page 4
Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Page 5
Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
Page 6
CAUTION! Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used bat- teries according to the manufacturer’s instructions.
Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
Product Specifications Intel® Xeon® Processor Scalable Family Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor TDP up to 205W Socket 2 x LGA 3647 Socket P0 ...
Page 12
Internal 1 x 18-pin power connector (system power rail) Connectors 1 x 18-pin power connector (CPU0 all power rail) 1 x 18-pin power connector (CPU1 all power rail) 4 x SlimSAS connectors 1 x TPM header ...
Page 13
System Aspeed® AST2500 management controller Management Avocent® MergePoint IPMI 2.0 web interface: Network settings Network security settings Hardware information Users control Services settings IPMI settings Sessions control LDAP settings Power control ...
Chapter 2 System Appearance Front View 4 5 6 7 8 9 10 Description Description Front panel LED and buttons 2.5-inch hard disk drive #4 System fan (GPU78_FAN) 2.5-inch hard disk drive #5 2.5-inch hard disk drive #0 2.5-inch hard disk drive #6 2.5-inch hard disk drive #1 2.5-inch hard disk drive #7 2.5-inch hard disk drive #2...
Front Panel LED and Buttons Name Color Status Description Green System is powered on Green Blink System is in ACPI S1 state (sleep mode) Power button • System is not powered on or in ACPI S5 state (power with LED off) •...
Rear System Button and LEDs Name Color Status Description Green System is powered on Green Blink System is in ACPI S1 state (sleep mode) Power button • System is not powered on or in ACPI S5 state with LED (power off) •...
Hard Disk Drive LEDs HDD Present RAID SKU LED1 Locate Rebuilding Fault Access (No Access) Disk LED Green ON(*1) Green (LED on Back Panel) Amber Amber No RAID configuration Green ON(*1) Green (via HBA, ICH) Removed HDD Slot (LED on Back Panel) Amber Amber Green...
Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
Removing Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the system cover: Remove the eight screws securing the cover. Slide the cover towards the rear and remove the cover in the direction of the arrow.
Removing and Installing the Fan Duct Follow these instructions to remove/install the fan duct: Lift up to remove the fan duct To install the fan duct, align the tabs at the front of the fan duct with the slots in the system fan compartment as shown in the image below, and then push down the fan duct into chassis until its firmly seats System Hardware Installation...
Installing the CPU and Heat Sink Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
Page 26
CPU0 CPU1 System Hardware Installation - 26 -...
Installing the Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
3-4-2 Installing a Memory Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR4 DIMMs on this motherboard. Follow these instructions to install the Memory: Insert the DIMM memory module vertically into the DIMM slot, and push it down.
Installing the GPU Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to installing a PCI card.
Page 30
(For GPU1/GPU2/GPU3/GPU4) Front Rear System Hardware Installation - 30 -...
Page 31
GPU_3/GPU_15 (Slot 3) GPU_4/GPU_16 (Slot 4) GPU_1/GPU_13 (Slot 1) GPU_2/GPU_14 (Slot 2) • If the GPU card supports 225W, connect the 2 x 4 power cable.. • If the GPU card supports 300W, connect the 2x4 and 2x3 power cables. - 31 - System Hardware Installation...
Page 32
For GPU6/GPU7/GPU8/GPU9/GPU10/GPU11/GPU12 Follow these instructions to install the GPU card: [For GPU9/GPU10/GPU11/GPU12] Loosen and remove the two screws securing the PCI cage at the top of the system. [For GPU5/GPU6/GPU7/GPU8] Loosen and remove the single screw at the top of the system and the two screws at the rear of the system securing the PCI cage.
Page 33
(For GPU5/GPU6/GPU7/GPU8) Front Rear - 33 - System Hardware Installation...
Page 34
GPU_7/GPU_11 GPU_8/GPU_12 (Slot 3) (Slot 4) GPU_6/GPU_10 (Slot 2) GPU_5/GPU_9 (Slot 1) Please insert the PCI cage into the selected slot with the correct orientation. See illustration below for instruction. System Hardware Installation - 34 -...
Page 35
• If the GPU card supports 225W, connect the 2 x 4 power cable.. • If the GPU card supports 300W, connect the 2x4 and 2x3 power cables. - 35 - System Hardware Installation...
Installing a PCI Express Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to installing a PCI card.
Page 38
Follow these instructions to install a PCI Express x16 card on left side of the system: Loosen the thumbnail screw securing the PCI Express card bracket on the left side of the system. Remove the PCI Express card bracket from the system. Install the PCI Express card into the bracket.
Page 39
IMPORTANT If you are installing an add-on card and want to support NVMe hard drives, the OCP switch located near the proprietary PCIe x8 mezzanine connector at the rear of the system (#37 in the 4-1 Motherboard Components section) must be set to off (labeled 1), as seen in the image below. Once the OCP switch is set to off, the proprietary PCIe x8 mezzanine connector's functionality will be disabled, and the Slimline 4i connectors for NVMe storage (#15 &...
Installing an OCP Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to installing a PCI card.
Slide the hard drive tray into the bay until it locks in place. CAUTION! We strongly recommend using enterprise level hard disk drives in the Gigabyte server system. For more information of recommended HDDs, please visit the Gigabyte website: https://www.gigabyte.com and search for the specific product QVL from Support & Downloads.
Page 43
IMPORTANT • If a RAID card is installed in your system, RAID functionality must first be enabled via the jumper located on the hard disk back plane board. See Section 3-6 "Hard Disk Back Plane Board Jumper Setting" for details on the jumper settings. •...
Replacing the FAN Assembly CAUTION! Before you remove or install the system fans follow these steps: • Make sure the system is not turned on or connected to the AC power.. • Disconnect all necessary cable connections. Failure to observe these warnings could result in personal injury or damage to the equipment.
Page 45
Airflow direction Airflow direction [For SYS_FAN1/SYS_FAN2] Disconnect the fan cable and then lift up the fan assembly from the chassis. Reverse the previous steps to install the replacement fan assembly. - 45 - System Hardware Installation...
Page 46
Airflow direction [For GPU12E_FAN/GPU56E_FAN] Disconnect the fan cable and then loosen and remove the screws securing the fan cage. Remove the fan cage from the system Reverse the previous steps to install the replacement fan assembly. System Hardware Installation - 46 -...
Page 47
Airflow direction CAUTION! • To avoid fan cable damage, please make sure the fan cables are firmly seated in the cable routing hooks. - 47 - System Hardware Installation...
3-10 Replacing the Power Supply CAUTION! • In order to reduce the risk of injury from electric shock, disconnect AC power from the power supply before removing it from the system. Follow these instructions to replace the power supply: Pull up the power supply handle and press the retaining clip on the right side of the power supply along the direction of the arrow.
3-11 Cable Routing Suggest Cable Suggest Cable HDD BPB Signal Cable #1 (Aqua Green) 1x3 Power Cable (Teal) Fan Power Cables (Red) Slimline SAS Cable 2 (Grass Green) Slimline SAS Cable 1 (Magenta) Main Power Cable (Yellow) CPU Power Cable (Blue) SMD Cable (Pink) Front IO Cable (Green) HDD BPB Power Cable (Orange)
Page 50
This page intentionally left blank System Hardware Installation - 50 -...
Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters and loading operating system, etc. BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
Page 56
Main This setup page includes all the items in standard compatible BIOS. Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
Page 58
Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note) BMC Firmware Version (Note) Displays BMC firmware version information.
Page 59
LAN MAC Address (Note) Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. (Note) Functions available on selected models. - 59 - BIOS Setup...
Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components. Select a submenu item, then press Enter to access the related submenu screen. BIOS Setup - 60 -...
5-2-1 iSCSI Configuration iSCSI Initiator Name Add an Attempt Press [Enter] for configuration of advanced items. Delete Attempts Press [Enter] for configuration of advanced items. Change Attempt Order Press [Enter] for configuration of advanced items. - 61 - BIOS Setup...
Intel(R) Ethernet Connection X722 for 10GBASE-T Intel(R) Ethernet Connection X722 for 10GbE NIC Configuration Press [Enter] for configuration of advanced items of the selected network device port. Blink LEDs Identifies the physical network port by blinking the associated LED. Press the numeric keys to adjust desired values. UEFI Driver Displays the technical specifications for the Network Interface Controller.
Page 65
Adapter PBA Displays the technical specifications for the Network Interface Controller. Device Name Displays the technical specifications for the Network Interface Controller. Chip Type Displays the technical specifications for the Network Interface Controller. PCI Device ID Displays the technical specifications for the Network Interface Controller. PCI Address Displays the technical specifications for the Network Interface Controller.
Page 66
5-2-3-1 NIC Configuration Link Speed Allows for automatic link speed adjustment. Default setting is Auto Negotiated. Wake On LAN Enables power on of the system via LAN. Note that configuring Wake on LAN in the operating system does not change the value of this setting, but does override the behavior of Wake on LAN in OS controlled power states.
5-2-4 Trusted Computing Configuration Security Device Support Enable/Disable the TPM support feature. Options available: Enable/Disable. Default setting is Enable. Current Status Information Displays current TPM status information. - 67 - BIOS Setup...
5-2-5 Serial Port Console Redirection COM1/COM2 Serial Over LAN Console Redirection (Note) Select whether to enable console redirection for specified device. Console redirection enables the users to manage the system from a remote location. Options available: Enabled/Disabled. Default setting is Disabled. Legacy Console Redirection Selects a COM port for Legacy serial redirection.
Page 69
5-2-5-1 COM1/COM2 Serial Over LAN/Legacy/Serial Port for Out-of-Band EMS Console Redirection Settings - 69 - BIOS Setup...
Page 70
COM1/COM2 Serial Over LAN Console Redirection Settings Terminal Type Selects a terminal type to be used for console redirection. Options available: VT100/VT100+/ANSI /VT-UTF8. Default setting is ANSI. Bits per second Selects the transfer rate for console redirection. Options available: 9600/19200/38400/57600/115200. Default setting is 115200. Data Bits Selects the number of data bits used for console redirection.
Page 71
Parity A parity bit can be sent with the data bits to detect some transmission errors. Even: parity bit is 0 if the num of 1's in the data bits is even. Odd: parity bit is 0 if num of 1's in the data bits is odd. Mark: parity bit is always 1.
Page 73
AMI SIO Driver Version Displays the AMI SIO driver version information. Super IO Chip Logical Device(s) Configuration [*Active*] Serial Port 1/Serial Port 2 Press [Enter] for configuration of advanced items. Serial Port 1/Serial Port 2 Configuration Use This Device When set to Enabled allows you to configure the Serial port 1/Serial port 2 settings. When set to Disabled, displays no configuration for the serial port.
Page 74
Options available for Serial Port 2: Use Automatic Settings IO=2F8h; IRQ=3; DMA; IO=3F8h; IRQ=3, 4, 5, 7, 9, 10, 11, 12; DMA; IO=2F8h; IRQ=3, 4, 5, 7, 9, 10, 11, 12; DMA; IO=3E8h; IRQ=3, 4, 5, 7, 9, 10, 11, 12; DMA; IO=2E8h;...
5-2-7 PCI Subsystem Settings PCI Bus Driver Version Displays the PCI Bus Driver version information. PCI Express Slot #1/#2/#3/#4/#5/#6/#7/#8 I/O ROM (Note) When enabled, this setting will initialize the device expansion ROM for the related PCI-E slot. Options available: Enabled/Disabled. Default setting is Enabled. Onboard LAN1 Controller (Note) Enable/Disable the onboard LAN1 devices.
5-2-9 CSM Configuration Compatibility Support Module Configuration CSM Support (Note) Enable/Disable the Compatibility Support Module (CSM) support. Options available: Enabled/Disabled. Default setting is Disabled. CSM16 Module Version Displays the CSM module version information. Please note that this item is configurable when CSM Support is set to Enabled. Advanced items prompt when this item is set to Enabled.
Page 78
GateA20 Active When set to Upon Request, GA20 can be disabled using BIOS services. When set to Always, GA20 cannot be disabled; this option is useful when any RT code is executed above 1MB. Options available: Upon Request/Always. Default setting is Upon Request. Please note that this item is configurable when CSM Support is set to Enabled.
5-2-12 USB Configuration USB Configuration USB Devices: Displays the USB devices connected to the system. XHCI Hand-off Enable/Disable the XHCI (USB 3.0) Hand-off support. Options available: Enabled/Disabled. Default setting is Enabled. USB Mass Storage Driver Support (Note) Enable/Disable the USB Mass Storage Driver Support. Options available: Enabled/Disabled.
5-2-13 Chipset Configuration Restore on AC Power Loss (Note) Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Stay Off, the system remains off after power shutdown.
Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of North Bridge and South Bridge. Select a submenu item, then press Enter to access the related submenu screen. - 83 - BIOS Setup...
5-3-1 Processor Configuration Processor Configuration Pre-Socket Configuration Press [Enter] for configuration of advanced items. Processor Socket/Processor ID/Processor Frequency/Processor Max Raito/ Processor Min Raio/Microcode Revision/L1 Cache RAM/L2 Cache RAM/L3 Cache RAM/ Processor 0/1 Version Displays the technical specifications for the installed processor. BIOS Setup - 84 -...
Page 85
Hyper-Threading [All] The Hyper Threading Technology allows a single processor to execute two or more separate threads concurrently. When hyper-threading is enabled, multi-threaded software applications can execute their threads, thereby improving performance. Options available: Enable/Disable. Default setting is Enable. Enable Intel(R) TXT Enables ord isables the Intel Trusted Execution Technology support function.
Page 87
CPU Socket 0/1 Configuration Press [Enter] for configuration of advanced items. Core Disable Bitmap(Hex) (for CPU socket 0/1) Number of Cores to enable. 0 means all cores. FFFFFFF means to disable all cores. The maximum value depends on the number of CPUs available. Press the numeric keys to adjust desired values. - 87 - BIOS Setup...
5-3-2 Common RefCode Configuration Common RefCode Configuration MMIO High Base Selects the MMIO High Base setting. Options available: 56T/40T/24T/16T/4T/1T. Default setting is 56T. MMIO High Granularity Size Selects the allocation size used to assign mmioh resources. Total mmioh space can be up to 32xgranularity.
UPI General Configuration Press [Enter] to change the UPI general settings. UPI Status Press [Enter] to view the UPI status. Link Frequency Select Selects the UPI link frequency. Options available: 9.6GB/10.4GB/Auto. Default setting is Auto. BIOS Setup - 90 -...
5-3-4 Memory Configuration Integrated Memory Controller (iMC) Enforce POR When set to Enable, the system enforces Plan Of Record restrictions for DDR4 frequency and voltage programming. When set to Auto, the system sets it to the MRC default settings. Options available: Auto/POR/Disable. Default setting is Enable. Memory Frequency Configures the memory frequency.
Page 92
Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not. Options available: Enable/Disable. Default setting is Disable. Memory Topology Press [Enter] for configuration of advanced items. Memory RAS Configuration Press [Enter] for configuration of advanced items. BIOS Setup - 92 -...
Page 94
5-3-4-2 Memory RAS Configuration Memory RAS Configuration Setup RAS Type Displays the RAS type. Static Virtual Lockstep Mode Enable/Disable the Static Virtual Lockstep mode. Options available: Disable/Enable. Default setting is Disable. Mirror Mode Mirror Mode will set entire 1LM/2LM memory in system to be mirrored, consequently reducing the memory capacity by half.
5-3-5 IIO Configuration IIO Configuration Intel® VT for Directed I/O (VT-d) Press [Enter] for configuration of advanced items. Inter® VMD technology Press [Enter] for configuration of advanced items. - 95 - BIOS Setup...
Page 96
5-3-5-1 Intel® VT for Directed I/O (VT-d) Intel® VT for Directed I/O (VT-d) Intel® VT for Directed I/O (VT-d) Enable/Disable the Intel VT for Directed I/O (VT-d) support function by reporting the I/O device assignment to VMM through DMAR ACPI Tables. Options available: Enable/Disable.
Page 97
5-3-5-2 Intel® VMD Technology Intel® VMD technology Intel® VMD Configuration Enable/Disable the Intel VMD support function. Options available: Enable/Disable. Default setting is Disable. - 97 - BIOS Setup...
5-3-6 Advanced Power Management Configuration Advanced Power Management Configuration CPU P State Control Press [Enter] for configuration of advanced items. Hardware PM State Control Press [Enter] to configure the Hardware P-State setting. CPU C State Control Press [Enter] for configuration of advanced items. Package C State Control Press [Enter] to configure the Package C State limit.
Page 99
5-3-6-1 CPU P State Control SpeedStep (Pstates) Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load. Options available: Enable/Disable. Default setting is Enable. Turbo Mode When this item is enabled, the processor will automatically ramp up the clock speed of 1-2 of its processing cores to improve its performance.
Page 100
5-3-6-2 Hardware PM State Control Hardware P-States When this item is disabled, the processor hardware chooses a P-state based on OS Request (Legacy P-States). In Native mode, the processor hardware chooses a P-state based on OS guidance. In Out of Band mode, the processor hardware autonomously chooses a P-state (with no OS guidance). Options available: Disable/Native Mode/Out of Band Mode/Native Mode with No Legacy Support.
Page 101
5-3-6-3 CPU C State Control Autonomous Core C-State Enable/Disable the Autonomous Core C-State Control. Options available: Enable/Disable. Default setting is Disable. CPU C6 Report Allows you to determine whether to let the CPU enter C6 mode in system halt state. When enabled, the CPU core frequency and voltage will be reduced during system halt state to decrease power consumption.
Page 102
5-3-6-4 Package C State Control Package C-State Configures the state for the C-State package limit. Options available: C0/C1 state/C2 state/C6(non Retention) state/C6(Retention) state/No Limit/Auto. Default setting is Auto. BIOS Setup - 102 -...
Page 103
5-3-6-5 CPU-Advanced PM Tuning Energy Perf BIAS Enters the Energy Perf BIAS submenu. Power Performance Tuning (Note) Tunes the Power Performance Configuration mode. When enabled, uses IA32_ENERGY_PERF_BIAS input from the core. When disabled, uses alternate performance BIAS input from ENERGY_PERF_ BIAS_CONFIG.
Page 104
ENERGY_PERF_BIAS_CFG mode Selects the Energy Performance Bias Configuration Mode. Options available: Performance/Balanced Performance/Balanced Power/Power. Default setting is Balanced Performance. Please note that this item is configurable when Power Performance Tuning is set to BIOS Con- trols EPB. BIOS Setup - 104 -...
5-3-7 PCH Configuration PCH Configuration PCH SATA Configuration Press [Enter] for configuration of advanced items. PCH sSATA Configuration Press [Enter] for configuration of advanced items. - 105 - BIOS Setup...
Page 106
5-3-7-1 PCH SATA Configuration PCH SATA Configuration SATA Controller(s) Enable/Disable SATA controller. Options available: Enable/Disable. Default setting is Enable. Configure SATA as Configure on chip SATA type. AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality. Then the RAID function is disabled and cannot be access the RAID setup utility at boot time.
Page 107
RAID Mode: When set to RAID, the SATA controller enables both its RAID and AHCI functions. You will be allows access the RAID setup utility at boot time. Options available: AHCI/RAID. Default setting is AHCI. Alternate Device ID on RAID (Note 1) Enable/Disable Alternate Device ID on RAID mode.
Page 108
5-3-7-2 PCH sSATA Configuration PCH sSATA Configuration sSATA Controller(s) Enable/Disable sSATA controller. Options available: Enable/Disable. Default setting is Enable. Configure sSATA as Configure on chip SATA type. AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality. Then the RAID function is disabled and cannot be access the RAID setup utility at boot time.
Page 109
RAID Mode: When set to RAID, the SATA controller enables both its RAID and AHCI functions. You will be allows access the RAID setup utility at boot time. Options available: AHCI/RAID. Default setting is AHCI. Alternate Device ID on RAID (Note 1) Enable/Disable Alternate Device ID on RAID mode.
5-3-8 Miscellaneous Configuration Miscellaneous Configuration Active Video Selects the active video type. Options available: Auto/Onboard Device/PCIE Device. Default setting is Auto. BIOS Setup - 110 -...
5-3-9 Server ME Configuration General ME Configuration Operational Firmware Version Displays Operational Firmware version information. ME Firmware Status #1/#2 Displays ME Firmware status information. Current State (for ME Firmware) Displays ME Firmware current status information. Error Code (for ME Firmware) Displays ME Firmware status error code.
Server Management Menu FRB-2 Timer Enable/Disable FRB-2 timer (POST timer). Options available: Enabled/Disabled. Default setting is Disabled. FRB-2 Timer timeout Configure the FRB2 Timer timeout. Options available: 3 minutes/4 minutes/5 minutes/6 minutes. Default setting is 6 minutes. Please note that this item is configurable when FRB-2 Timer is set to Enabled. FRB-2 Timer Policy Configure the FRB2 Timer policy.
Page 117
System Event Log Press [Enter] for configuration of advanced items. View FRU Information Press [Enter] to view the advanced items. BMC network configuration Press [Enter] for configuration of advanced items. IPv6 BMC Network Configuration Press [Enter] for configuration of advanced items. - 117 - BIOS Setup...
5-4-1 System Event Log Enabling/Disabling Options SEL Components Change this item to enable or disable all features of System Event Logging during boot. Options available: Enabled/Disabled. Default setting is Enabled. Erasing Settings Erasing SEL Choose options for erasing SEL. Options available: No/Yes, On next reset/Yes, On every reset. Default setting is No. When SEL is Full Choose options for reactions to a full SEL.
5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased - 119 - BIOS Setup...
5-4-3 BMC Network Configuration Select NCSI and Dedicated LAN Switch NCSI and dedicated LAN and send KCS command. Options available: Do Nothing/Mode1 (Dedicated)/Mode2(NSCI)/Mode3 (Failover). Default setting is Mode1 (Dedicated). Lan Channel 1 Configuration Address source Select to configure LAN channel parameters statically or dynamically (DHCP). Do nothing option will not modify any BMC network parameters during BIOS phase.
5-4-4 IPv6 BMC Network Configuration IPv6 BMC Lan Channel 1 IPv6 BMC Lan Option Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS phase. Options available: Enable/Disable. Default setting is Enable. IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically (by BIOS or BMC).
Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
5-5-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. System Mode Displays the system is in User mode or Setup mode. Secure Boot Displays the Secure Boot function is actived or not actived. Vendor Keys Displays the Vendor Keys function is actived or not actived.
Page 124
5-5-1-1 Key Management Provision Factory Defaults Allows to provision factory default Secure Boot keys when system is in Setup Mode. Options available: Enabled/Disabled. Default setting is Disabled. Install Factory Default Keys Installs all factory default keys. It will force the system in User Mode. Options available: Yes/No.
Page 125
Forbidden Signatures (DBX) Displays the current status of the Forbidden Signature Database. Press [Enter] to configure a new dbx or load additional dbx from storage devices. Options available: Set New/Append. Authorized TimeStamps (DBT) Displays the current status of the Authorized TimeStamps Database. Press [Enter] to configure a new DBT or load additional DBT from storage devices.
Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Boot Configuration Setup Prompt Timeout Number of seconds to wait for setup activation key. 65535 (0xFFFF) means indefinite waiting. Press the numeric keys to input the desired values.
Page 127
UEFI Network Drive BBS Priorities Press [Enter] to configure the boot priority. UEFI Application Boot Priorities Press [Enter] to configure the boot priority. - 127 - BIOS Setup...
5-6-1 UEFI NETWORK Drive BBS Priorities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable.
5-6-2 UEFI Application Boot Priorities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. - 129 - BIOS Setup...
Save & Exit Menu The Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press Enter. Save Options Save Changes and Exit Saves changes made and closes the BIOS setup. Options available: Yes/No.
Page 131
Default Options Restore Defaults Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components and you choose to load these settings, the system might not function properly. Options available: Yes/No.
5-8-4 Intel UPI POST Codes Initialize KTIRC inuput structure default values 0xA0 Collect info such as SBSP, Boot Mode, Reset type etc 0xA1 Setup IO SADs in SBSP to access the config space 0xA2 Setup up minimum path between SBSP & other sockets 0xA3 Add the node to the tree Parse the LEP of the discovered socket...
SAD setup error 0xDB RC Behavior: System Halt Unsupported topology 0xDC RC Behavior: System Halt SBSP cannot find KPIRC TXEQ Parameters for this 0xDD link in GetSocketLinkEparams(). No retry. RC Behavior: System Halt 5-8-6 Intel MRC POST Codes Detect DIMM population 0xB0 Set DDR frequency 0xB1...
5-8-8 Intel PM POST Codes Start of PPM structure initialization 0xD0 PPM CSR programming 0xD1 PPM MSR programming 0xD2 Start of PState transition init 0xD3 PPM exit 0xD4 PPM On ready to boot event 0xD5 5-8-9 Intel PM POST Codes Start of IIO early Initialization 0xE0 Pre Link training...
BIOS POST Beep code (AMI standard) 5-9-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...
5-10 BIOS Recovery Instruction The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: Change xxx.ROM to amiboot.rom.