REMOVAL AND REASSEMBLY OF LIFT BALE (continued)
REASSEMBLY PROCEDURE
1. Place the lift bail onto the IDEALARC
from the top, lowering straight onto the unit.
2. Using a 9/16" socket wrench, attach the four
bolts and associated washers mounting the lift
bail to the base assembly.
3. Using a 9/16" socket wrench, attach the four
bolts mounting the lift bail to the main trans-
former assembly.
TROUBLESHOOTING AND REPAIR
®
DC-1000
IDEALARC
4. Using a 3/8" socket wrench, attach the two
screws holding the input contactor bracket to
the lift bail.
5. Reattach leads #217 and #222 to resistor R2.
6. Reattach or reconnect any cables or wire ties
previously removed.
7. Using a 5/16 (8mm) nut driver or flat head
screw driver, attach 20 screws (ten per side) to
secure case sides, and 2 screws to secure top.
®