Lincoln Electric IDEALARC DC-1000 Service Manual page 101

Hide thumbs Also See for IDEALARC DC-1000:
Table of Contents

Advertisement

F-67
Testing is required after the removal of any mechanical part that could affect the machineʼs elec-
trical characteristics, or if any electrical components are repaired or replaced.
Input Volts/Phase/Hertz
230/3/60
460/3/60
575/3/60
Mode
Variable Voltage
Auxiliary Output (#31-#32)
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE - AT MINIMUM OUTPUT
Mode
Constant Voltage Innershield
MINIMUM ACCEPTABLE OUTPUT VOLTAGE AT MAXIMUM OUTPUT
Mode
Variable Voltage
Constant Voltage Submerged Arc
Constant Voltage Submerged Arc
at 500 Amp Terminal
TROUBLESHOOTING AND REPAIR
RETEST AFTER REPAIR
INPUT IDLE AMPS AND WATTS
Maximum Idle Amps
OPEN CIRCUIT VOLTAGES
Input Hertz
SETTINGS
Input Hertz
SETTINGS
IDEALARC
14.0
7.0
5.6
60
60
60
140 Amps @ 14/18 VDC
Input Hertz
60
1250 Amps @ 47/52 VDC
60
1250 Amps @ 47/52 VDC
60
625 Amps @ 53/58 VDC
®
DC-1000
Maximum Idle KW
2.0
2.0
2.0
Open Circuit Volts
74/76 DC
122/124 AC
Load
Load
F-67