F-42
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
CONSTANT VOLTAGE INNERSHIELD - MAXIMUM
TROUBLESHOOTING AND REPAIR
OUTPUT SETTINGS – NO LOAD
This is the typical DC open circuit volt-
age waveform generated from a prop-
erly operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 2 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+) probe to
positive 1000 Amp terminal, (-) probe
to negative terminal.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
IDEALARC
®
DC-1000
F-42