031: Number Of Rpq Diskettes Required; 032: Request Rpq Parameter List (Configuration Support C And T Only); 111: Number Of Category B Terminals (Configuration Support A, B, And C Only) - IBM 3270 Manual

Information display system; control unit
Hide thumbs Also See for 3270:
Table of Contents

Advertisement

Once a printer authorization matrix has been defined, sequence number 021
is no longer displayed when a customized 3274 Control Unit is being
updated. Instead, the defined matrix is displayed. If the entire matrix is
deleted, sequence number 021 is again displayed during each updating
procedure until a new matrix is defined. Any time the initial customizing
procedure is performed, the sequence number 021 is displayed and the
printer authorization matrix must be redefined if it is still required.
031: Number of RPQ Diskettes Required
Enter the number of RPQ diskettes required (0, 1, 2, or 3) in step 7 on the
Initial Customizing Procedure Form.
032: Request RPQ Parameter List (Configuration Support C and T Only)
Enter a 1 if you require the RPQ parameter list; enter a 0 if not. If you
enter a 1 here, sequence number 033 (RPQ Parameters) is displayed, with
spaces for parameter information. If you enter a 0, sequence number 033 is
not displayed.
Note: An RPQ parameter list is required by certain RPQs. Specific
information about this list, sequence number 033 format, and
implementation is supplied with the RPQ.
· 111: Number of Category B Terminals (Configuration Support A, B, and C
Only)
3-38
Models lC, 21C, and 31C: Enter a 2-digit number (00 to 16) specifying the
number of Category B terminals that it is possible to attach to your 3274.
(The actual number you have attached at any given time may be smaller
than this number.)
Model 51C: If category B terminals are to be used, enter 04 in response to
this sequence number in step 8 on the Initial Customizing Procedure Form.
Note: A Model 51C with the Loop Adapter (feature 4850) does not allow
Category B terminals to be attached.
See sequence number 112 for a description of category types.
Notes:
1.
A 2-digit number must be entered. If necessary, use a leading zero; for
example, to specify
4,
enter
04.
2.
Specify the number of Category B terminals in multiples of 4 (maximum
of 16).

Advertisement