Starting And Stopping The Week Program; Changing The Appliance's Standard Week Program - A.O. Smith cyclone BFC - 80 Installation And Service Manual

A.o. smith gas water heater installation user and service manual
Table of Contents

Advertisement

11
The appliance's default week program switches the
appliance on every day at 00:00 and off at 23:59. The
default water temperature setting is 65°C.
If you want, you can change every setting in the
appliance's standard week program.
If the water temperature becomes too low while the
week program is running, the appliance will run
through the heating cycle
(9.3 "The appliance's
heating cycle")
and return to the week program.
This following are discussed:

Starting and stopping the week program

Changing the appliance's standard week program

Adding times to a week program
Deleting times from a week program
11.5 Starting and stopping the week
program
The week program can be started up from any other
operating mode, as follows:
1.
: WEEK PROGRAM | START OPERATION
Confirm with
.
A week program can be shut down simply by
activating a different operating mode, for example the
"ON mode".
11.6 Changing the appliance's standard
week program
Note
First fill-in the desired week program on the
supplied week program card.
A week program is made up of a number of
programmable periods in which you can have the
appliance switch on and off. A period consists of:
switch-on time: day of the week, hours and
minutes:
switch-off time: hours and minutes;
the water temperature setting;
on/off setting for a program-controlled pump.
Note
The switch-off time must always be followed by a
switch-off time on the same day of the week. A
maximum of three periods may be programmed per
day. You can program a maximum of 21 periods.
Call up the menu for the week program as follows:
: WEEK PROGRAM | PROGRAM OVERVIEW.
Confirm with
.
WEEK PROGRAM
START OPERATION
^»PROGRAM OVERVIEW
È
58
Main menu
The display shows the menu for the week program,
see the figure below. With the default setting, the
program switches on and off every day at 00:00 and
23:59 hours respectively, the water temperature is
65°C and the pump is switched on (P).
ON »SU
OFF SU
ON
OFF MO
ON
OFF TU
ON
OFF WE
ON
OFF TH
ON
OFF FR
ON
OFF SA
Example
As an example, we will set the switch-on time for
Sunday to 08:15 hours, and the matching switch-off
time to 12:45 hours. The water temperature will be set
to 75 °C and the pump will run continuously.
The following settings are entered one by one via the
menu: the switch-on time, the switch-off time, the
desired water temperature, and the mode of the
program-controlled pump.
11.6.1
1. Bring the cursor to SU
ON
OFF
Tset 65ÉC
PUMP ON
2. Use
ON
OFF
Tset 65ÉC
PUMP ON
3. Use
DAY TIME
Tset
00:00 65ÉC P
23:59
MO
00:00 65ÉC P
23:59
TU
00:00 65ÉC P
23:59
WE
00:00 65ÉC P
23:59
TH
00:00 65ÉC P
23:59
FR
00:00 65ÉC P
23:59
SA
00:00 65ÉC P
23:59
INSERT
DELETE
START OPERATION
Week program: setting the switch-
on time
Confirm with
.
»SU 00:00
SU 23:59
SAVE
The day indicated by » flashes.
and
to set the desired day. In the example
this is SU (Sunday).
Confirm with
.
SU»00:00
SU 00:59
SAVE
The cursor moves to the hour digits, which flash.
and
to set the hours. In the example, this
is 08.