Excell ELW Plus User Manual page 5

Waterproof weighing scale
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
a) Anode(+) of battery should be connected with Anode of product battery (usually red
cable)
b) Cathode(-) of battery should be connected with Cathode of product battery (usually
brown cable or black cable)
Safety warnings
1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.
2. The hydrogen will be resolved when using or charging the battery and it will cause explosion
when approaches fire.
No burning
Caution Corrosion
 Dry battery: 4 x D size dry batteries (alkaline, IEC LR20) (not included)
Power Consumption: 30 mA (system no backlight)
 Wireless Charging: AirCharge
Power Supply: adapter 100V~240V(50~60Hz) Battery: 3.7V 6100mA (18650 dual battery)
AirCharge: 12V/1.5A (15W) output QI TX module
 Wipower(out of production): DC5V/2A (5W)output QI TX module
Power Consumption:
a. While the scale is charging, the spacing between charging plate and scale shall be within
2mm. Metal objects are prohibited between the spacing; otherwise, it might cause
overheating or burning.
b. Charging without battery will cause charging indicator to flash red and green. Please
avoid that.
020261XX/020264XX/020268XX
020311XX/020314XX/020318XX
Warning explosion
36 mA (system backlight)
29 mA (system no backlight)
80 mA (system backlight)
Brown cable(or black cable)
connected with Cathode of
battery
Red cable connected with
Anode of battery
Children faraway
about 400 hours
about 200 hours
about 102 hours
about 37 hours
ZSMT300000351