Lincoln Electric IDEALARC DC-600 Service Manual page 88

Hide thumbs Also See for IDEALARC DC-600:
Table of Contents

Advertisement

F-44
5. Connect the Tester to the SCR 1 as shown in
Figure F.17.
a. Connect Tester lead (A) to the anode.
b. Connect Tester lead (C) to the cathode.
c. Connect Tester lead (G) to the gate.
6. Close switch SW-1.
NOTE: Switch SW-2 should be open.
7. Read meter for zero voltage.
a. If the voltage reading is higher than zero,
the SCR is shorted.
8. Close or keep closed switch SW-1
9. Close switch SW-2 for 2 seconds and release
and read meter.
a. If the voltage is 3 - 6 volts while the switch
is closed and after the switch is open, the
SCR is functioning.
b. If the voltages is 3-6 volts only when the
switch is closed or there is no voltage
when the switch is closed, the SCR is
defective.
NOTE:
Be sure battery is functioning
properly.
A low battery can affect the
results of the test. Repeat Battery Test
Procedure in Step 4 if needed.
TROUBLESHOOTING AND REPAIR
ACTIVE SCR TEST (continued)
IDEALARC
10. Open switch SW-1.
11. Reconnect the Tester leads. See Figure F.17.
a. Connect Tester lead (A) to the cathode.
b. Connect Tester lead (C) to the anode.
c. Disconnect Test lead (G) from the gate.
12. Close switch SW-1.
13. Read meter for zero voltage.
a. If the voltage is zero, the SCR is function-
ing.
b. If the voltage is higher than zero, the SCR
is shorted.
14. Perform the Active Test Procedure outlined in
Steps 5-13 for SCR's 2-6.
15. Replace all SCR assemblies that do not pass
the above tests.
16. Replace all Molex Plugs onto the Firing Board
and Control Board.
®
DC-600
F-44