Lincoln Electric IDEALARC DC-600 Service Manual page 109

Hide thumbs Also See for IDEALARC DC-600:
Table of Contents

Advertisement

F-65
Should a machine under test be rejected for any reason requiring the removal of any mechanical part
that could affect the machine's electrical characteristics, or if any electrical components are repaired or
replaced, the machine must be retested.
Input volts/Phase/Hertz
208/3/60
230/3/60
380/3/60
416/3/60
460/3/60
550/3/60
575/3/60
200/3/50
220/3/50
260/3/50
346/3/60
380/3/50
400/3/50
415/3/50
440/3/50
500/3/50
550/3/50
Mode
Variable Voltage
Variable Voltage
Auxiliary Output (#31-#32)
Auxiliary Output (#31-#32)
TROUBLESHOOTING AND REPAIR
RETEST AFTER REPAIR
INPUT IDLE AMPS AND WATTS
Maximum Idle Amps
OPEN CIRCUIT VOLTAGES
Input Hertz
IDEALARC
Input volts/Phase/Hertz
14.4
13.0
7.9
7.2
6.5
5.4
5.2
30.8
28.0
23.7
17.8
16.2
15.4
14.8
14.0
12.3
11.2
60
50
60
50
®
DC-600
1.488
1.488
1.488
1.488
1.488
1.488
1.488
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
Open Circuit Volts
74/70 DC
71/67 DC
123/117 AC
118/112 AC
F-65