JOINING KIT INS TALL ATION (CONT.)
Kit Sizes: 60" (1524 mm) / 72" (1828.8 mm) / 78" (1981.2 mm) / 90" (2286 mm) / 102" (2591 mm) / 120" (3048 mm)
14. Walk the joined units into their final installation
location.
15. Verify the level of the appliances. Level the units as
needed.
16. Restore power to the units and turn the units on.
17. After three (3) minutes of runtime, open the
doors individually and verify correct door switch
operation. When operating correctly, the following
should occur:
• Unless set otherwise, the lights turn on and off
with the door openings.
• The evaporator (interior) fan turns on and off
with door openings.
• There is a low-pitched click from the control
board area when the door opens or shuts.
18. Install the joining kit grill.
Return the magnet bracket screws to their original locations
FIG. 17.
FIG. 19.
Installed joining rainshield.
TEC_TM_009 REV. J_EN
I N S T A L L A T I O N
Verify the appliance fronts are flush. Adjust the units
FIG. 15.
accordingly.
Verify the gap(s) between appliances is (are) even throughout.
FIG. 16.
FIG. 18.
Installed joining bracket.
Connect the reed switches with the original wire configurations.
FIG. 20.
10/06/2023
1
2
T R- 3 0 / 3 6 IN STA L L M A NUA L
3
4
Page 41 of 80