JOINING KIT INS TALL ATION (CONT.)
Kit Sizes: 60" (1524 mm) / 72" (1828.8 mm) / 78" (1981.2 mm) / 90" (2286 mm) / 102" (2591 mm) / 120" (3048 mm)
NO T E: IF F OUR (4) W IR E S A R E
C ONNEC T ED T O T HE R EED SW I T CH,
BE SUR E T O CL E A R LY L A BEL T HE
W IR E S ' O R IGIN A L L O C AT ION S BEF O R E
DI S C ONNEC T ING T HE R EED SW I T CH.
W IR E L O C AT ION I S
A P P L I A NCE ' S OP ER AT ION. SEE F IG. 5.
3. Remove the reed switch wire from the rainshield.
See figs. 6 and 7.
4. Remove the rainshield. See figs. 8-10.
5. Repeat steps 1-4 for each unit of the joined
installation.
6. Remove the inner magnet brackets (see figs. 11
and 12). Then, thread and tighten the magnet
bracket screws. Discard the magnet bracket.
NO T E: BE SUR E T O R E T UR N M A GNE T
BR A CK E T S CR E W S T O T HEIR O R IGIN A L
P O SI T ION S; T HE S CR E W S SUP P O R T T HE
C A S T O R A S SEMBLY HOU SING.
FIG. 9.
Rainshield screw locations.
TEC_TM_009 REV. J_EN
I N S T A L L A T I O N
CR I T IC A L
T O T HE
10/06/2023
2
1
Label the original wire locations
FIG. 5.
switch.
Remove the p-clip holding
FIG. 6.
the wire to the rainshield.
Bracket screw location. Other bracket not shown.
FIG. 8.
Remove the screws from the metal channel.
FIG. 10.
T R- 3 0 / 3 6 IN STA L L M A NUA L
3
4
disconnecting the reed
BEFORE
Pull the reed switch wire
FIG. 7.
through the rainshield bushing.