TRUE FOOD SERVICE EQUIPMENT, INC. 2001 East Terra Lane • P.O. Box 970 • O’Fallon, Missouri 63366 (636)-240-2400 • FAX (636)272-2408 • INT’L FAX (636)272-7546 • (800)325-6152 Parts Department (800)424-TRUE • Parts Department FAX# (636)272-9471 TABLE OF CONTENTS Safety Information...
Page 2
True Food Service Equipment, Inc. True Food Service Equipment, Inc..www.truemfg.com ..www.truemfg.com ...
You have selected one of the finest commercial refrigeration units made. It is manufactured under strict quality controls with only the best quality materials available. Your TRUE cooler when properly maintained will give you many Use this appliance for its intended purpose as described in...
Leave the shelves in place so that children may not easily climb inside. USE OF EXTENSION CORDS NEVER USE AN EXTENSION CORD! TRUE will not warranty any refrigerator that has been connected to an extension cord..www.truemfg.com ..www.truemfg.com ...
(North America Use Only!) NEMA plugs TRUE uses these types of plugs. If you do not have the right outlet have a certified electrician install the correct power source.
... www.truemfg.com ... True Food Service Equipment, Inc. True Food Service Equipment, Inc. Before you start to install your True unit, carefully inspect it for freight damage. If damage is discov- ered, immediately file a claim with the delivery freight carrier.
True Food Service Equipment, Inc. True Food Service Equipment, Inc. INSTALLATION / OPERATION INSTRUCTIONS INSTALLATION / OPERATION INSTRUCTIONS LOCATING Step 2 A. Place packing material behind cabinet as a cushion. Carefully lay the unit on its back to remove skid.
(100°F+, 38°C+), you may want to install an exhaust fan. Warning Warranty is void if ventilation is insufficient. B. Proper leveling of your True cooler is critical to operating success (for non-mobile models). Effective condensate removal and door operation will be effected by leveling.
True Food Service Equipment, Inc. True Food Service Equipment, Inc. INSTALLATION / OPERATION INSTRUCTIONS INSTALLATION / OPERATION INSTRUCTIONS CONDUCTORS AND CIRCUITS Wire Gauge for 2% Voltage Drop in Supply Circuits 115 Volt Amps Wire Gauge for 2% Voltage Drop in Supply Circuits...
True dealer or recommended service agent. D. Good air flow in your True unit is critical. Be careful to load product so that it neither presses against the back wall, nor comes within four inches of the evaporator housing.
True Food Service Equipment, Inc. True Food Service Equipment, Inc. MAINTENANCE, CARE & CLEANING MAINTENANCE, CARE & CLEANING MAINTENANCE, CARE & CLEANING CLEANING THE CONDENSER COIL When using electrical appliances, basic safety precautions should be followed, including the following: REQUIRED TOOLS: •...
5. When finished be sure to replace the louvered grill. The grill protects the condenser. 6. Reconnect the electrical power to the unit. If you have any questions, please call True Manufacturing at 636-240-2400 or 800-325-6152 and ask for the Service Department. Service Department Availability Monday-Friday 7:30 a.m. to 5:30p.m.
True Food Service Equipment, Inc. True Food Service Equipment, Inc. MAINTENANCE, CARE & CLEANING MAINTENANCE, CARE & CLEANING TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY! TERMS: Cut-out - Temperature sensed by the controller that shuts the compressor off. Cut-in - Temperature sensed by the controller that turns the compressor on.
Oxygen helps maintain the passivity film on stainless steel. 7. Hydrochloric acid (muriatic acid) should never be used on stainless steel 8. Regularly restore/passivate stainless steel ... www.truemfg.com ..www.truemfg.com ... True Food Service Equipment, Inc. True Food Service Equipment, Inc.
Page 15
True Food Service Equipment, Inc. True Food Service Equipment, Inc. MAINTENANCE, CARE & CLEANING MAINTENANCE, CARE & CLEANING Stainless Steel Equipment Care and Cleaning Recommended cleaners for certain situations / environments of stainless steel A) Soap, ammonia and detergent medallion applied with a cloth or sponge can be used for routine cleaning.
TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit. TRUE’s obligation under this warranty is limited to a period of one (1) year from the date of original installation or 15 months after shipment date from TRUE, whichever occurs first.