7. How to adjust the needle bar height
Preparation: Remove the needle threading system unit.
1. Remove the cord band.
2. Loosen the upper screw and remove the lower screw.
LED fix base.
3. Slide the LED fixing base, loosen the hexagonal screw of the needle bar,
and move the needle bar up and down to adjust the needle bar height.
11.43
11