Shure MXA310 User Manual page 36

Table array microphone
Hide thumbs Also See for MXA310:
Table of Contents

Advertisement

Problem
Automixing is disabled or is missing a channel
Microphone does not power on
Specifications
All specifications measured from cardioid polar pattern. Values for all patterns are within ± 3 dB of these specifications unless
otherwise noted.
General
Polar Pattern
All channels independently adjustable
Cardioid, hypercardioid, supercardioid, toroid, omnidirectional, bidirectional
Connector Type
RJ45
Power Requirements
Power over Ethernet (PoE), Class 0
Power Consumption
4W, maximum
Weight
362 g (0.8 lbs)
Dimensions
H x W x D
3.6 x 13.4 x 13.4 cm (1.4 x 5.3 x 5.3 in.)
Control Software
Shure Designer or web application
Operating Temperature Range
−6.7°C (20°F) to 40°C (104°F)
Storage Temperature Range
−29°C (­20°F) to 74°C (165°F)
Solution
Automix is automatically disabled when you turn on toroid
Omnidirectional channels are not sent to the automix chan­
nel
The network switch must supply Power over Ethernet. Other­
wise, a PoE injector must be used
Check network cables and connections
Shure Incorporated
36/42

Advertisement