Siemens SIMATIC NET RUGGEDCOM RX1510 Equipment Manual page 53

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1510:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
Environmental Type Tests
Military Standard Tests
MIL-STD-810G
44
Description
Dielectric Strength
Fast Transient
Oscillatory
Radiated RFI
ESD
Test
IEC 60068-2-1
Cold Temperature
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
IEC 61373
IEC 60255-21-3
Test
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Signal ports
DC Power Ports
AC Power Ports
Earth ground ports
Signal ports
DC Power Ports
AC Power Ports
Enclosure ports
Enclosure Contact
Enclosure Air
Description
Test Ad
Dry Heat
Test Bd
Humidity (Damp
Test Db
Heat, Cyclic)
Vibration
Shock
Bump
Long Life (Random Vibration)
Shock
Seismic
Description
Altitude
Test Levels
5 kV
2 kV
1.5 kV
2 kV
± 4 kV @ 2.5 kHz
± 4 kV
2.5 kV common mode @1MHz
2.5 kV common
1 kV differential mode @ 1 MHz
35 V/m
± 8 kV
± 15 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10-150 Hz
30 g @ 11 ms
10 g @ 16 ms
Category 1 Class B
Method A
Test Levels
12192 m (40000 ft) @ 40 °C, 90
minutes
RUGGEDCOM RX1510
Equipment Manual, 10/2023, C79000-G8976-1055-25
Severity
Levels
 
 
 
Class 2
Class 2
Class 1
 
 
Level 2

Advertisement

Table of Contents
loading

Table of Contents