Siemens SIMATIC NET RUGGEDCOM RX1510 Equipment Manual page 42

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1510:
Table of Contents

Advertisement

3.
4.
5.
Installing a Power Module
To install a power module, do the following:
1.
2.
3.
4.
5.
6.
RUGGEDCOM RX1510
Equipment Manual, 10/2023, C79000-G8976-1055-25
Chassis
1
Screws
2
Power Supply
3
Figure 4.5
Removing a Power Supply
Slide the module out of the chassis.
Disconnect the power supply wiring from the terminal block. Alternatively, for
convenience, remove the terminal block with the wiring still connected and set
it aside to be connected later to the new module.
Install a new or blank module to prevent the ingress of dust and dirt.
If equipped, remove the existing module.
If applicable, connect the supplied terminal block to the module or connect the
terminal block from the previous module.
Confirm or connect the wiring from the power supply to the module. For more
information, refer to "Connecting Power" (Page 11).
Insert the module into the empty slot.
Chassis
1
Screws
2
Power Module
3
Figure 4.6
Installing a Power Module
Hand-tighten the screws to secure the power module to the chassis.
Turn on power to the device and confirm the module is receiving and supplying
power. This is indicated by the LEDs on the module.
4.4 Installing/Removing Power Modules
Modules
1
2
3
33

Advertisement

Table of Contents
loading

Table of Contents