Capacity Calibration - Excell FWH3 Service Manual

Printer indicator
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
3-2 Capacity Calibration ⇒
Please make sure MINI JUMPER of SWA1 is connected to ADJ on PC board before
setting. Please make sure MINI JUMPER of SWA1 is connected to LOCK on PC board
after setting.
Refer to "Appendix 1: Specification Table".
Press
key
Press
key
Press
key
Press
and
key,
input the digital value.
Press
key
Press
and
key,
input the digital value.
Press
key
Press
and
input the digital value.
Press
key
key,
Internal code test
01 02 03
06 05 04 on/off
Internal value
key = high digital key (0,1,2,3,4,5,6,7,8,9 input)
key = the right shift key;
key = the confirmation key;
Units option mode
1 = kg
2 = lb
eg.
Single unit
Single unit
Bi-units
Tri-units
kg
Tri-units
Select Units option mode
The fourth digit ⇒ 0 = kg, 1 = g
The fifth digit
Full scale + 9d ( "lb"F.S = "kg"F.S×2 )
kg
eg.
"3kg×1g"and"30kg×10g"and"300kg×100g" input 03009
"6kg×2g"and"60kg×20g"and"600kg×200g" input 06018
"15kg×5g"and"150kg×50g" input 015045
kg
Weight specification
The first digit ⇒ division (1,2,5)
The second digit ⇒ decimal digital (≦5)
The third digit ⇒ 1: division multiplies 10;
The fourth digit ⇒ zero setting
kg
The fifth digit ⇒
11
E6 ⇒ Internal value is too high.
(﹥550 000 )
E7 ⇒ Internal value is too low.
(﹤150 000 )
3 = twg
4 = hkg
"kg" please input 100x0
"lb"
please input 200x0
"kg", "lb" please input 120x0
"kg", "lb", "twg" please input 123x0
"kg", "lb", "hkg" please input 124x0
⇒ 0 = lb,1 = lb, oz
0: division does not multiply 10;
0 = 10d
1 = 1d
2 = 2d
5 = 5d
6 = 6d
7 = 7d
0 = no cut mark
1 = multi-interval
2 = multi-range
3 = 3d 4 = 4d
8 = 8d 9 = 9d