Weight Calibration - Excell FWH3 Service Manual

Printer indicator
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
3-1 Weight Calibration ⇒
Please make sure MINI JUMPER of SWA1 is connected to ADJ on PC board before
setting. Please make sure MINI JUMPER of SWA1 is connected to LOCK on PC board
after setting.
Before doing weight calibration, please make sure that there is no weight in the platter.
Press
or
Press
key
Press
key
Press
and
key
input the
weight value
Put weight value (3 kg),
then press
key
Press
key
When stable, the buzzer
After calibration, enter into
weighing mode.
key to select F0 function ⇒ the display shows
kg
.
kg
.
kg
.
sounds
kg
.
Press
key to exit
and back to F0 mode.
Have done zero calibration.
Press
the zero value.
Press
desired unit weight (kg or lb).
9
to power off to revise
key to select the