Download Print this page

Emerson Rosemount 3144P Quick Start Manual page 18

Temperature transmitters
Hide thumbs Also See for Rosemount 3144P:

Advertisement

Quick Start Guide
5.3.3  I6 Canada Intrinsic Safety and Division 2
Certificate
Standards
Markings
5.3.4  K6 Canada Explosionproof, Intrinsic Safety and Division 2
Certificate
Standards
Markings
5.4 
Europe
5.4.1  E1 ATEX Flameproof
Certificate
Standards
Markings
Specific Conditions of Use (X):
1. Flameproof joints are not intended for repair.
2. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that cause electrostatic build-up
on painted surfaces and only clean the painted surfaces with a
damp cloth. If paint is ordered through a special option code,
contact the manufacturer for more information.
18
1242650
C22.2 No. 61010-1-12 + UPD1: 2015 + UPD2: 2016, C22.2
No. 25-17, C22.2 No.94.2-20 Third Edition, CSA Std C22.2
No. 213-17, CAN/CSA-60079-0:19, CAN/CSA-60079-11:14
IS CL I DIV 1, GP A, B, C, D; T4, CL II DIV 1, GP E, F, G; CL
III; T4 Ex ia IIC T4 Ga; Ex ia IIIC T94 ºC Da; T4 (-50 °C ≤ T
≤ +60 °C)
NI CL I DIV 2, GP A, B, C, D (-60 °C ≤ T
when installed per Rosemount drawing 03144-5076;
Type 4X
1242650
C22.2 No. 61010-1-12 + UPD1: 2015 + UPD2: 2016, C22.2
No. 25-17, C22.2 No.94.2-20 Third Edition, CSA Std C22.2
No. 213-17, CAN/CSA-60079-0:19, CAN/CSA-60079-11:14,
CSA Std C22.2 No. 30-M1986
XP CL 1 DIV 1, GP A, B, C, D
DIP CL II DIV 1, GP E, F, G; CL III;
(-50 °C ≤ T
≤ +85 °C); Type 4X; seal not required.
a
DEKRA 19ATEX0076 X
EN IEC 60079-0: 2018, EN 60079-1: 2014, EN
60079-31:2014
II 2 G Ex db IIC T6...T1 Gb, T6(-60 °C ≤ T
T5...T1(-60 °C ≤ T
≤ +80 °C)
a
January 2024
≤ +85 °C)
a
≤ +70 °C),
a
Rosemount 3144P
a

Advertisement

loading