Printer Feature
8825 - EV4 Controller Specifications
Hardware Specifications
Physical Characteristics
Electrical Requirements
Agency Approvals
I/O Ports
Serial
Parallel
SCSI
VPI
TCP/IP
Network
IEEE 1394
Description/Specifications
CPU: Power PC 8240 (603e) operating at 250 MHz clock speed.
RAM: 64MB DRAM is standard. Maximum RAM is 256MB. Two DIMM Slots accommodate 64 or 128MB, PC100, DIMMs.
Hard disk: Ultra SCSI, 7200 rpm internal hard disk drive.
The Controller is attached to the side panel of the 8825 Printer as an embedded device.
100 - 250 VAC auto-ranging power supply
Safety: UL 1950, CA22.2 No. 950 (CUL), EN 60950 (CE Mark)
EMC:
CE Mark, FCC Class A, Canada Radio Interference Regulations Class A, VCCI Class 1
Two 9 pin Host serial ports provided. One is used by the 8825 Digital Solution scanner when this option is connected. The second is
used as an input port for receiving data via serial port connection.
(IEEE 1284 Compliant) High density port connector provided.
Optional 50 pin SCSI-2 card available.
Optional card available.
10/100 Ethernet Network Interface Port provided: RJ-45 connection, supporting TCP/IP only.
Optional External Ethernet Adapter available to support TCP/IP, Novell 3.x, 4.x, 5.x, and NetBEUI.
Interface supporting the Synergix Scan System
68