Fluid Line Accessories - Graco UNICARB 308936 Instructions-Parts List Manual

85 kv electrostatic air-assisted spray gun 100 psi (7 bar, 0.7 mpa) maximum working air pressure 3000 psi (207 bar, 20.7 mpa) maximum working fluid pressure
Table of Contents

Advertisement

S
R
KEY
A* Bleed-type Air Shutoff Valve
B
Air Line Filter
H
Fluid Shutoff Valve
K
Pressure Gauge
L* Grounded Braid Type Fluid Hose
with spring guards
M Gun Fluid Inlet (1/4 npsm)
Fig. 1

Fluid Line Accessories

1. Install a fluid filter (S) and drain valve (R) at the
pump outlet. Filtering the fluid will help remove
coarse particles and sediment that could clog the
spray tip.
WARNING
INJECTION HAZARD
The fluid drain valve (R) is required in
your system to assist in relieving fluid
pressure in the supply system, hose and
gun; triggering the gun to relieve pressure may not
be sufficient. Install a drain valve close to the
pump's fluid outlet. The drain valve reduces the risk
of serious injury, including fluid injection and
splashing in the eyes or on the skin.
Installation
A
H
K
L
R
Y
N
Gun Air Regulator
P
Gun Air Shut-off Valve
Q* Graco Electrically Conductive
Air Supply Hose
(1/4 npsm x 1/4 npsm LH)
R* Fluid Drain Valve
S
Fluid Filter
(Refer to Fig. 1)
N
P
B
Q
W PRO AA4500/UNICARB Spray Gun
X
Gun Air Inlet (1/4 npsm LH)
Y
Shrouded/Vented Waste Container
*
Equipment required for safe operation of
system. Must be purchased separately.
See ACCESSORIES.
2. Install a fluid regulator (J) on the fluid line to con-
trol fluid pressure to the gun.
X
M
WARNING
SIGN
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro aa4500965722UnicarbPro aa4500 unicarb b seriesPro aa4500 unicarb 965722

Table of Contents