5-1. Installing Welding Generator

Movement
Location / Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
Mounting
OM-237 711 Page 20
SECTION 5 − INSTALLATION
OR
OR
18 in
(460 mm)
18 in
(460 mm)
1
.
A complete Parts List is available at www.MillerWelds.com
OR
install2 2008-01 − Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712
!
Do not move or operate unit
where it could tip.
!
Do not lift unit from end.
!
Do not weld on base. Welding
on base can cause fuel tank fire
or explosion. Bolt unit down
using holes provided in base.
!
Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
NOTICE − Do not install unit where air
flow is restricted or engine may over-
heat.
.
See Section 4-3 for lifting eye rat-
ing.
Mounting:
!
Do not mount unit by support-
ing the base only at the four
mounting holes. Do not use
flexible mounts.
Use cross-
supports to adequately sup-
port unit and prevent damage
to base.
1
Cross-Supports
Mount unit on flat surface or use
cross-supports to support base. See
Section 4-3.