ELECTRICAL SYSTEM
MOTOR-GENERATOR
BELT
-Continued
VOLTAGE REGULATOR
A satisfactory generator charging rate is maintained
by the voltage regulator.
If the regulator fails to
operate correctly, see your I nternational Harvester
dealer.
Adjusting the Motor-Generator Belt
Loosen the motor-generator brace bolt and mount-
ing bolts.
NOTE:
Never
place a jumper
lead between,
or
accidentally
bridge,
the "BAT"
terminal
and the
"F"
terminal
on the regulator,
as this will damage
the regu lator.
Move the generator away from the engine until the
tension on the belt is correct.
NOTE: Under no circumstances should a pry bar
be used on the motor-generator
to obtain belt
tension as damage to the bearings will result.
LIGHTS
Tighten mounting bolts and brace bolt.
Lights are optional
on all models except the
Models 149 and 169.
Removing and Replacing the Motor-Generator Belt
The
headlights
are sealed-beam
units.
Refer
to
"SPECIFICATIONS"
when
replacement
is neces-
sary.
To replace the taillight
lamp, remove the lens from
the taillight
and r~place.
Refer to "SPECIFICA-TIONS",
FUSE (Electric
Lighting)
Always use the same capacity fuse for replacement.
Refer to "Specifications".
If the lights fail, check
the fuse.
1. Mounting bolts2.
Motor generator brace bolt3.
Motor generator belt
The fuse is located in a fuse housing in the line at
the back of the instrument panel.
To install a new fuse, press in on the fuse housing
cap and turn counterclockwise
to remove it from
the fuse housing. Remove the old fuse and replace
it with a new one. Then reassemble the cap to the
housing. Remove the fuel tank if necessary to
reach the fuse.
Replace the motor-generator belt when it becomes
badly worn. To remove the old belt, loosen the
motor-generator
brace bolt and mounting bolts.
Move the generator in toward the engine and slip
the old belt off the pulleys and over the crank-
shaft. I nstall the new belt in the reverse order of
removal and adjust the belt to the proper tension.
Before working
on any part of the electrical
system, disconnect the battery ground cable at the
battery negative (-) terminal.
Do not reconnect
this cable until all work has been completed. This
will prevent shorting and damage to any of the
electrical units. Examine the electrical cables occa-
sionally to be sure they are not being frayed by
contact with adjacent parts.
NOTE:
If tractor
is equil
drive
belt
must also be
generator belt.