Certification
6.2 EMC and environmental type tests
Environmental type tests
IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
IEC 60068-2-31
62
Test
IEC 60068-2-1
Cold temperature
IEC 60068-2-2
Change of
temperature
Humidity (damp
heat, cyclic)
Humidity (damp
heat, steady state)
IEC 60529
Description
Test Ad
Dry heat
Test Bd
Test Nb
Test Db
Test Cab
Vibration
Shock
Bump
Seismic
Ingress protection
Free fall
Test Ec
Test levels
Severity levels
-40 °C (-40
°F), 16 Hours
85 °C (185
°F), 16 hours
5 Cycles, -40 to 85°
C (40 to 185° F)
93% upper
temperature, 97%
lower temperature
55 °C (131
°F), 6 Cycles
10 days @ 55 °C
(131 °F) and 93%
relative humidity
Level 2 (2 g @
10 to 150 Hz)
Level 2 (30
g @ 11 mS)
Level 1 (10
g @ 16 mS)
Method A, class 2
IP3x
25 cm
Equipment Manual, 10/2023, C79000-G8976-1359-19
 
 
 
 
 
Class 2
Class 2
Class 1
Class 2
 
 
RUGGEDCOM RST2228