Calibrating the several monitors
A remote control adjustment for the several monitors is available by using the
maintenance cable (Maximum 4 monitors).
Example (4 monitors)
Maintenance
cable
1.
Plug the maintenance cable into the REMOTE IN (Mini 6 pin)
connector of the first monitor and the other end of the cable into the
serial port (D-Sub 9 pin) of the PC.
2.
Plug the maintenance cable into the REMOTE OUT (D-Sub 9 pin)
connector of the first monitor and other end of the cable into the
REMOTE IN (Mini 6 pin) of the second monitor.
3.
Plug the second monitor OUT and third monitor IN, and third
monitor OUT and fourth monitor IN.
4.
Please identify the ID number to each monitor by using the OSD
adjustment (see page 14).
Set the ID number in order from the left monitor to the right (From front
view).
5.
Plug the photo sensor to the photo sensor connector (Mini DIN 8
pin) of any monitor.