All models
IMPORTANT!
This freestanding cooker must be connected to the mains power supply only by a
z
suitably qualified person.
This freestanding cooker must be earthed.
z
Always disconnect electric supply cord from the wall outlet or service disconnect
z
before servicing this appliance.
The rating label is
located under the
control panel
Wiring diagrams are
also in the service
summary, attached
to the inside of the
toe kick panel
12

ELECTRICAL CONNECTION

IMPORTANT!
This cooker must be connected to the mains power supply only
z
by a suitably qualified person. This cooker must be earthed.
If the installation requires alterations to the domestic electrical system, call a qualified
z
electrician. The electrician should also check that the electrical system is suitable for the
electricity drawn by the cooker.
The appliance must be connected to the mains electricity supply, checking that the
z
voltage corresponds to the value given in the rating plate and that the electrical cable
sections can withstand the load specified on the plate.
A suitable disconnection switch must be incorporated in the permanent wiring, mounted
z
and positioned to comply with the local wiring rules and regulations. The switch must
be of an approved type installed in the fixed wiring and provide a 3mm air gap contact
separation in all poles in accordance with the local wiring rules.
A switch of the approved type with a 3mm air gap must be installed in the active (phase)
z
conductor of the fixed wiring.
The switch must always be accessible.
z
The power supply cable must not touch any hot parts and must be positioned so that it
z
does not exceed 75°C at any point.
This cooker must be connected to a suitable double pole control unit adjacent to the
z
cooker. No diversity can be applied to this control unit.
This appliance must be connected to the electrical supply using a cable fitted with an
z
appropriately rated plug. The plug must be compatible with the socket-outlet fitted to
the final subcircuit in the fixed wiring that is intended to supply the appliance.
A wiring diagram
Replacing the power cord
label is attached
Replacements should only be made by a qualified electrician.
to the back of
z
the freestanding
Use a cable according to the applicable local regulations.
z
cooker
IMPORTANT!
An improper 220/240 VAC power supply will cause malfunction, damage to this
z
appliance, and possibly create a condition of shock hazard.
Improper connection of aluminium house wiring can result in a fire or shock hazard.
z
Use only connectors designed and certified for connecting to aluminium wire.
MODEL
RIV3-915
*AS/NZS 3000 (table C5) Calculated Circuit Load, this is less than the total connected load listed
on the rating label.
IMPORTANT!
The fourth prong (round grounding pin) should not, under any circumstances,
be cut or removed.
SERVICE*
FREQUENCY
40 A
50 Hz
POWER
16.1 kW