CONVENIENCE OUTLETS

WARNING
Failure to follow this caution could result in personal injury
or death.
Units with convenience outlet circuits may use multiple dis-
connects. Check convenience outlet for power status before
opening unit for service. Locate its disconnect switch, if ap-
propriate, and open it. Lock-out and tag-out this switch, if
necessary.
Two types of convenience outlets are offered on 582K mod-
els: non-powered and unit-powered. Both types provide a 125-
volt GFCI (ground-fault circuit interrupter) duplex receptacle
rated at 15A behind a hinged waterproof access cover, located
on the end panel of the unit. See Fig. 29.
Figure 30 shows the Convenience Outlet Utilization label
which is located below the convenience outlet.
CONVENIENCE
OUTLET GFCI
PWD-CO FUSE
SWITCH
PWD-CO
TRANSFORMER
Fig. 29 — Convenience Outlet Location
Fig. 30 — Convenience Outlet Utilization
Notice Label
NOTE: Unit powered convenience outlets are not available as fac-
tory installed options for single phase (-J voltage code models).
Installing Weatherproof Cover
A weatherproof while-in-use cover for the factory-installed con-
venience outlets is now required by UL standards. This cover can-
not be factory-mounted due its depth; it must be installed at unit
installation. For shipment, the convenience outlet is covered with
a blank cover plate.
On units with electro-mechanical controls the weatherproof
cover kit is shipped in the unit's control box. The kit includes
the hinged cover, a backing plate, and gasket. On units with a
factory installed direct digital controller (RTU Open) the
weatherproof cover kit is secured to the basepan underneath
the control box (see Fig. 31).
Failure to follow this caution could result in personal injury
or death.
Disconnect all power to unit and convenience outlet. Lock-
out and tag-out all power prior to installation.
WEATHERPROOF
COVER
Fig. 31 — Weatherproof Cover — Shipping Location on
Units with Factory Installed DDC
1.
Remove the blank cover plate at the convenience outlet;
discard the blank cover.
2.
Loosen the two screws at the GFCI duplex outlet, until
approximately
1/
2
exposed. Press the gasket over the screw heads.
3.
Slip the backing plate over the screw heads at the keyhole
slots and align with the gasket; tighten the two screws
until snug (do not over-tighten).
4.
Mount the weatherproof cover to the backing plate as
shown in Fig. 32.
5.
Remove two slot fillers in the bottom of the cover to per-
mit service tool cords to exit the cover.
6.
Check for full closing and latching.
COVER - WHILE-IN-USE
WEATHERPROOF
Fig. 32 — Weatherproof Cover Installation
18
WARNING
in. (13 mm) under screw heads is
GFCI RECEPTACLE
NOT INCLUDED
GASKET
BASEPLATE FOR
GFCI RECEPTACLE