Rated Indoor Airflow - Bryant Legacy 582K04-07 Installation Instructions Manual

Table of Contents

Advertisement

Rated Indoor Airflow

Table 1 lists the rated indoor airflow used for the AHRI
efficiency rating for the units covered in this document.
Position:
Example:
Unit Type
582 - Gas Heat RTU, Legacy™ Line
Model
K - Puron
®
(R-410A) Refrigerant
Voltage
E = 460-3-60
J = 208/230-1-60
P = 208/230-3-60
(See 582J/580J models for 575 volt units)
Cooling Tons
04 - 3 tons
05 - 4 tons
06 - 5 tons
07 - 6 tons
Refrig. System/Gas Heat Options
A = Standard One Stage cooling models/Nat. Gas Heat
C = Standard One Stage cooling models/SS HX Heat
G = One-Stage cooling models/Alum Heat Exchanger
with Perfect Humidity™
J = One-Stage cooling models/Stainless Steel Exchanger
with Perfect Humidity
N = Two-Stage cooling models/Single Circuit with Alum
Exchanger (07 only)
Q = Two-Stage cooling models/Single Circuit with Stainless
Exchanger (07 only)
R = Two-Stage cooling models/Single Circuit with Alum
Exchanger and Perfect Humidity (07 only)
T = Two-Stage cooling models/Single Circuit with Stainless
Exchanger and Perfect Humidity (07 only)
Heat Level Input (Single-Phase)
065 = 65,000
090 = 90,000
130 = 130,000
Heat Level Input (Three-Phase)
067 = 67,000
110 = 110,000
150 = 150,000
Note: On single phase (-J voltage code) models, the
following are not available as a factory installed option:
- Perfect Humidity
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer
- Powered 115 Volt Convenience Outlet
1
2
3
4
5
6
7
5
8
2
K
E
0
6
Fig. 1 — 582K04-07 Model Number Nomenclature (Example)
Table 1 — Rated Indoor Airflow
MODEL NUMBER
582K*04
582K*05
582K*06
582K*07
8
9 10 11 12 13 14 15 16 17
A
0
6
7
A
1
B
0
Outdoor Air Options
A = Electro-mechanical controls. Allows for use of all
B = Temperature Economizer, Barometric Relief,
E = Temperature Economizer, Barometric Relief,
H = Enthalpy Economizer, Barometric Relief,
L = Enthalpy Economizer, Barometric Relief,
Q = Motorized 2 Position Damper
U = Temperature Economizer, Barometric Relief,
W = Enthalpy Economizer, Barometric Relief, Ultra Low Leak
Indoor Fan Options
1 = Standard Static Vane Axial Fan
2 = Medium Static Vane Axial Fan Option
3 = High Static Vane Axial Fan Option
Coil Options (RTPF) (Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
3
RATED INDOOR AIRFLOW (CFM)
A
A
Packaging and Control
A = Standard Packaging, electro-mechanical
controls, no intake or exhaust option. Will
allow for use of all field-installed
economizers, manual or 2-position damper.
B = LTL Packaging, electro-mechanical
controls, no intake or exhaust option. Will
allow for use of all field-installed
economizers, manual or 2-position damper.
C = Standard Packaging, electro-mechanical
controls that require W7220 EconoMi$er X
F = LTL Packaging, electro-mechanical
controls that require W7220 EconoMi$er X
Factory Installed Options
0A = None
NOTE: See the 582K 3 to 6 ton Price Pages
for a complete list of factory installed
options.
field-installed economizers and dampers.
Standard Leak (W7212 or W7220)
Standard Leak w/CO
(W7212 or W7220)
2
Standard Leak (W7212 or W7220)
Standard Leak w/CO
(W7212 or W7220)
2
Ultra Low Leak (W7220)
(W7220)
1050
1500
2000
2400
1118