Page D Write Protect; Test Mode Setting; Emergency Code; Emergency Mode - Sony Handycam Video 8 CCD-TR606E Service Manual

Table of Contents

Advertisement

2.
Page D write protect
Release/set the pageD write protect.
l
Page
1
l
Address
00
Data
Function
00
Normal (Write protect condition)
01
Release the write protect
3.
Test mode setting
Set/release each test mode. Release the protect (Page: I, Address:
00,
Data: 01) before setting the data.
l
Page
D
I
Address
01
J
Data
Function
00
Normal
Test mode 1
Various emergency prohibitions and releases
Drum, capstan, loading motor, reel, tape top and
01
end, DEW SP/LP automatic discrimination
prohibition, manual switching,
5
minutes pause
release prohibition
Power off prohibition/release by battery end
02
Test mode 2
Not used
Test mode 3
Track shift
Performs the track shift playback
03
Rear lock distinction prohibition during PB
SP/LP automatic discrimination prohibition.
manual switching
Test mode 4
Rear lock mode
04
Performs rear lock playback
SP/LP automatic discrimination prohibition.
manual switching
*
For page D, the data set will be recorded in the nonvolatile
memory by pressing the PAUSE button on the adjusting
remote commander. Take note that, in this case, the test mode
will not be released even if the main power has been turned
off(7.5 Vdc).
*
Be sure to return this address data to 00 after completing
adjustments/repairs and press the PAUSE button of the
adjusting remote commander.
4.
Emergency code
Fault (error) symptoms can be checked.
\ Page D
I
Address
06
First emergency code
...... First error code generated
\ Page D
Address
07
Last emergency code
...... Last error code generated (This data will be renewed each
time an error occurs.)
*
Be sure to rewrite the data of addresses 06 and 07 to 00 after
repairs/adjustments.
*
When rewriting the data, be sure to press the PAUSE button
of the remote commander after setting the data.
Code
Error Condition
00
No error
01
Loading motor error
02
Reel error during unloading
03
Reel errors at other times
04
Capstan error
05
FG error during drum start up
06
PG error during drum start up
07
FG error during normal drum conditions
08
PG error during normal drum conditions
09
Phase error during normal drum conditions
-210-
5.
Emergency mode
The operation mode can be checked during faults.
I
Page D
j
Address
08
First emergency mode
...... The operation mode when the first error is generated
I
Page D
I
Address
09
Last emergency mode
.... ··The operation mode when the last error is generated
(This data will be renewed each time an error occurs.)
*
Be sure to rewrite the data of addresses 08 and 09 to 00 after
repairs/adjustments.
*
When rewriting the data, be sure to press the PAUSE button
of the adjusting remote commander after setting the data
Code
Error Conditions
00
BEFOR INITIALIZE
01
EJECTED
02
NORMAL STOP
03
FF
04
NORMAL REC
06
NORMAL PB
07
PB PAUSE
12
LOADING
14
REC PAUSE
26
X1
27
1/5SLOW
31
UNLOADING
46
CUE
56
REVIEW
62
STOP TAPE END
66
X2
67
FRAME
72
STOP TAPE TOP
83
REWIND
85
REC REVIEW (
+)
95
REC REVIEW(-)
97
-PB PAUSE
A2
EMERGENCY LOADING
A5
EDIT SEARCH (
+)
B1
EMERGENCY UNLOADING
B2
STOP EMERGENCY 1
B5
EDIT SEARCH (-)
C2
STOP EMERGENCY 2
E2
STOP NO CASSETTE
F5
EDIT PAUSE
6.
Bit value discrimination
Bit values must be discriminated using the display data of the
adjusting remote commander for the following items. Use the
table below to discriminate if the bit value is "I" or "0".
Adjusting remote commander display
®-->
,-,
.
,-, ,-,
.
,-, ,-,
'-'
.
'-' '-'
.
'-' '-'
t
Page
L
L
L.-r::::::!___.
Address
~etermine
the values of bit
3
to bit
0
Determine the values of bit
7
to bit
4
Remote
Bit value
commander
bit
3
or
bit 2 or
bit 1 or
bit
0
or
display
bit
7
bit
6
bit
5
bit
4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A( Fl)
1
0
1
0
B(b)
1
0
1
1
C{c)
1
1
0
0
D{ cl)
1
1
0
1
E{l::)
1
1
1
0
F(l::)
1
1
1
1
(Example) If the remote commander display data is "SE", bit
values from bit7 to bit4 can be discriminated from
column®, and those from bit3 to bitO from column
@.
-211-