Sony Handycam Video 8 CCD-TR606E Service Manual page 107

Table of Contents

Advertisement

1
o.
Flang~
back adjustment
Chart for flange back adjustment
Subject
Placed 2000 ± 5 mm in front of
the lens
llluminance: 300 ±50 lux)
Measurement Point
Check the operations on the TV
Measuring Instrument
monitor
Adjustment Page
F
98 (WIDE H),
99(WIDEL),
Adjustment Address
9A(TELEH),
9B (TELEL),
9C (FOCUS H),
9D(FOCUSL)
Adjusting method:
Order
Page
Address
Data
Procedure
6
00
01
Releasing of protect.
2
F
98
03
Set the initial data, and press the PAUSE button.
99
26
9A
1C
9B
B5
9C
11
9D
03
3
Check that the center of the flange back adjustment
chart coincides with that of the exposure display at both
4
5
6
7
6
6
6
6
21
01
13
01
15
21
the zoom lens TELE end and the WIDE end.
Check that the data is 00.
(Flange back adjustable display)
Press the PAUSE button.
Press the PAUSE button.
( Thi• oo•bl~ •dj"'tmoo" to bo mriod out
automatically. Adjustments are performed at the
zoom lens TELE end first, and then at the WIDE
end. The adjustment data is automatically input
to page: F, addresses: 98 to 9D.
Check that the data is 01.
(Display indicating that flange back adjustment has
completed.)
Processing after Adjustments:
Order
Procedure
Turn on the main power supply (7 .5V)
(Out of focus if this is not carried out.)
-182-
)
Conditions
11. Flange back check
Subject
Measurement Point
Measuring Instrument
Specified Value
Checking method:
Order
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Page
6
6
6
F
6
6
Checking method:
Siemens star
(Placed 2m in front of the lens)
DDS display of the EVF or TV
monitor
D2=DJ±3
Address
Data
Procedure
Place the Siemens star 2m in front of the lens.
To open the IRIS, decrease the luminous intensity to the
siemens star up to a point before noise appears on the
image displayed on the monitor TV screen.
Expose the Siemens star at the TELE end.
Press the "Focus" button, and turn on the auto focus.
02
oc
Check that the DDS display is
00 0001.
(Focusing check)
Press the "Focus" button and turn off the auto focus.
Expose the simens star at the WIDE end.
00
01
Releasing of protect.
02
00
02
B8
Press the PAUSE button.
(Setting the focus position display mode)
Read the DDS display data (4 digits) and take it as D1.
Press the "Focus" button, and turn on the auto focus.
02
oc
Check that the DDS display is
00 0001.
(Focusing check)
02
00
Read the DDS display (focus position display) data and
take it as D2.
Check that D2=DI ± 3.
Order
Page
Address
Data
Procedure
F
02
00
Press the PAUSE button.
(Releasing the focus position display mode)
-183-
Conditions
Auto focus on
Zoom WIDE end
Auto focus off
Auto focus on
Zoom WIDE end
Auto focus on
Focusing condition

Advertisement

Table of Contents
loading

This manual is also suitable for:

Handycam video 8 rmt-706

Table of Contents