OPERATING CONTROLS
SWITCH
The ON-OFF switch for Single Phase machines is located on
the front portion of the motor, as shown at (A) Fig, 37.
Fig. 37
The ON-OFF switch for Three Phase machines is located on
the switch box, as shown at (B) Fig. 38.
Fig. 38
OVERLOAD PROTECTION
Your planer is provided with overioad protection which will
shut off the motor if the planer is overloaded or if line voltage
falls below safe levels. If the motor shuts off due to overload¬
ing or low voltage, proceed as follows for Single and Three
Phase machines: On Single Phase machines, shut off switch
(A) Fig. 39, let the motor cool for approximately five minutes
and push the reset button (B|, which will reset the overload
device. The motor can then be turned on again in itie usual
manner.
Fig. 39
On Three Phase machines, let the motor cool for approximately
five minutes. The overload block supplied with this planer will
automatically reset itself and the machine can be started again
by pushing the start button,
If the machine, either single or three phase, continually shuts
off due to overloading, the cause of overloading must be
corrected. If this happens, it is recommended you obtain
advice from a qualified electrician.
12