Drive System Maintenance; Changing The Transmission Fluid; Controls System Maintenance; Adjusting The Service/Parking Brake - Toro Greensmaster e1021 Operator's Manual

Hide thumbs Also See for Greensmaster e1021:
Table of Contents

Advertisement

Drive System
Maintenance
Changing the Transmission
Fluid
Service Interval: Every 750 hours/Yearly (whichever
comes first)
Note:
Refer to
Figure 33
Figure 33
1. Breather vent and adapter
assembly
2. Transmission
1.
Remove the breather vent and adapter assembly
from the transmission.
2.
Have an assistant tip the machine backwards
and place a pan under the transmission.
Note:
Use the pan to collect the transmission
fluid.
3.
Remove the drain plug from the transmission
and let the fluid drain out.
4.
Install the drain plug.
5.
Torque the drain plug to 4 to 5 N∙m (32 to 42
in-lb).
6.
Add 473 ml (16 fl oz) of Dexron VI synthetic
transmission fluid through the adapter vent.
7.
Install the breather vent and adapter assembly
and tighten it to 12 to 15 N∙m (110 to 130 in-lb).
for this procedure.
3. Drain plug
4. Drain pan
Controls System
Maintenance
Adjusting the
Service/Parking Brake
Adjust the service/parking brake if it slips during
operation.
1.
Disengage the parking brake.
2.
Measure the free play at the end of the
parking-brake handle
The handle free play should be between 12.7 to
25.4 mm (0.50 to 1 inch). If the free play is not
within this amount, proceed to step
the brake cable.
g340874
1. Parking-brake handle
3.
Perform the following steps to adjust the
brake-cable tension:
To increase the cable tension, loosen the
front-cable jam nut and tighten the rear jam
nut
(Figure
the tension if necessary.
To decrease the cable tension, loosen the
rear jam nut and tighten the front-cable jam
34
(Figure
34).
3
Figure 34
2. Appropriate free play of
12.7 to 25.4 mm (0.50 to
1 inch).
35). Repeat step
2
and adjust
to adjust
g373542

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greensmaster e1026Eflex 1021048350484504865