6. Fix the stator and rotor using the transport locks. To do this, tighten the bolts with the
specified tightening torques according to the table "Required property classes and tightening
torques for stator and rotor."
7. Remove the spacer foil. When the stator and rotor are correctly centered, the spacer film can
be easily removed by hand.
5.4

Specification of the installation side

Permissible installation side
Note
Only mount the stator and rotor on one side of the flange. It is not permissible to mount the
stator and rotor at both flange sides.
As a result of the inherent design, for the following motors, mounting is only permissible at the A
flange.
Table 5-3
Mounting at the A flange
1FW616
1FW6160-xxB10-2Pxx
1FW6160-xxB15-2Pxx
1FW6160-xxB15-0Wxx
1FW6160-xxB20-2Pxx
1FW6160-xxB20-0Wxx
1FW6 built-in torque motors
Operating Instructions, 09/2022, A5E52220812B AA
1FW619
1FW6190-xxB10-2Pxx
1FW6190-xxB15-2Pxx
1FW6190-xxB15-0Wxx
1FW6190-xxB20-2Pxx
1FW6190-xxB20-0Wxx
5.4 Specification of the installation side
1FW623
1FW6230-xxB15-0Wxx
1FW6230-xxB20-0Wxx
 
 
 
Installation
1FW629
1FW6290-xxB07-2Pxx
1FW6290-xxB11-2Pxx
1FW6290-xxB15-2Pxx
1FW6290-xxB20-2Pxx
 